Filtered by vendor Emerson
Subscriptions
Total
85 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2016-9347 | 1 Emerson | 4 Se4801t0x Redundant Wireless I\/o Card, Se4801t0x Redundant Wireless I\/o Card Firmware, Se4801t1x Simplex Wireless I\/o Card and 1 more | 2025-04-20 | N/A |
An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily. | ||||
CVE-2016-9345 | 1 Emerson | 1 Deltav | 2025-04-20 | N/A |
An issue was discovered in Emerson DeltaV Easy Security Management DeltaV V12.3, DeltaV V12.3.1, and DeltaV V13.3. Critical vulnerabilities may allow a local attacker to elevate privileges within the DeltaV control system. | ||||
CVE-2016-8348 | 1 Emerson | 1 Liebert Sitescan Web | 2025-04-20 | N/A |
An XML External Entity (XXE) issue was discovered in Emerson Liebert SiteScan Web Version 6.5, and prior. An attacker may enter malicious input to Liebert SiteScan through a weakly configured XML parser causing the application to execute arbitrary code or disclose file contents from a server or connected network. | ||||
CVE-2021-44463 | 1 Emerson | 1 Deltav | 2025-04-17 | 8.1 High |
Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. | ||||
CVE-2021-26264 | 1 Emerson | 2 Deltav Distributed Control System, Deltav Workstation | 2025-04-17 | 6.1 Medium |
A specially crafted script could cause the DeltaV Distributed Control System Controllers (All Versions) to restart and cause a denial-of-service condition. | ||||
CVE-2020-10632 | 1 Emerson | 1 Openenterprise Scada Server | 2025-04-16 | 8.8 High |
Inadequate folder security permissions in Emerson OpenEnterprise versions through 3.3.4 may allow modification of important configuration files, which could cause the system to fail or behave in an unpredictable manner. | ||||
CVE-2020-10640 | 1 Emerson | 1 Openenterprise Scada Server | 2025-04-16 | 10 Critical |
Emerson OpenEnterprise versions through 3.3.4 may allow an attacker to run an arbitrary commands with system privileges or perform remote code execution via a specific communication service. | ||||
CVE-2020-10636 | 1 Emerson | 1 Openenterprise Scada Server | 2025-04-16 | 6.5 Medium |
Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. | ||||
CVE-2020-16235 | 1 Emerson | 1 Openenterprise Scada Server | 2025-04-16 | 3.8 Low |
Inadequate encryption may allow the credentials used by Emerson OpenEnterprise, up through version 3.3.5, to access field devices and external systems to be obtained. | ||||
CVE-2022-2788 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 3.9 Low |
Emerson Electric's Proficy Machine Edition Version 9.80 and prior is vulnerable to CWE-29 Path Traversal: '\..\Filename', also known as a ZipSlip attack, through an upload procedure which enables attackers to implant a malicious .BLZ file on the PLC. The file can transfer through the engineering station onto Windows in a way that executes the malicious code. | ||||
CVE-2022-2792 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 6.6 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-284 Improper Access Control, and stores project data in a directory with improper access control lists. | ||||
CVE-2022-2790 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 5.9 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-347 Improper Verification of Cryptographic Signature, and does not properly verify compiled logic (PDT files) and data blocks data (BLD/BLK files). | ||||
CVE-2022-2789 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 4.7 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-345 Insufficient Verification of Data Authenticity, and can display logic that is different than the compiled logic. | ||||
CVE-2022-2793 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 5.9 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-353 Missing Support for Integrity Check, and has no authentication or authorization of data packets after establishing a connection for the SRTP protocol. | ||||
CVE-2022-2791 | 1 Emerson | 1 Proficy | 2025-04-16 | 5.9 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulnerable to CWE-434 Unrestricted Upload of File with Dangerous Type, and will upload any file written into the PLC logic folder to the connected PLC. | ||||
CVE-2013-2810 | 1 Emerson | 6 Dl 8000 Remote Terminal Unit, Dl 8000 Remote Terminal Unit Firmware, Roc 800 Remote Terminal Unit and 3 more | 2025-04-12 | N/A |
Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier allows remote attackers to execute arbitrary commands via a TCP replay attack. | ||||
CVE-2014-2350 | 1 Emerson | 1 Deltav | 2025-04-12 | N/A |
Emerson DeltaV 10.3.1, 11.3, 11.3.1, and 12.3 uses hardcoded credentials for diagnostic services, which allows remote attackers to bypass intended access restrictions via a TCP session, as demonstrated by a session that uses the telnet program. | ||||
CVE-2015-1008 | 1 Emerson | 1 Ams Device Manager | 2025-04-12 | N/A |
SQL injection vulnerability in Emerson AMS Device Manager before 13 allows remote authenticated users to gain privileges via malformed input. | ||||
CVE-2014-2349 | 1 Emerson | 1 Deltav | 2025-04-12 | N/A |
Emerson DeltaV 10.3.1, 11.3, 11.3.1, and 12.3 allows local users to modify or read configuration files by leveraging engineering-level privileges. | ||||
CVE-2013-0694 | 2 Emerson, Enea | 4 Dl 8000 Remote Terminal Unit, Roc 800 Remote Terminal Unit, Roc 800l Remote Terminal Unit and 1 more | 2025-04-11 | N/A |
The Emerson Process Management ROC800 RTU with software 3.50 and earlier, DL8000 RTU with software 2.30 and earlier, and ROC800L RTU with software 1.20 and earlier have hardcoded credentials in a ROM, which makes it easier for remote attackers to obtain shell access to the underlying OS by leveraging knowledge of the ROM contents from a product installation elsewhere. |