Filtered by vendor Br-automation
Subscriptions
Total
40 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-2637 | 1 Br-automation | 6 Automation Runtime, Mapp Cockpit, Mapp View and 3 more | 2025-04-24 | 7.2 High |
An Uncontrolled Search Path Element vulnerability in B&R Industrial Automation Scene Viewer, B&R Industrial Automation Automation Runtime, B&R Industrial Automation mapp Vision, B&R Industrial Automation mapp View, B&R Industrial Automation mapp Cockpit, B&R Industrial Automation mapp Safety, B&R Industrial Automation VC4, B&R Industrial Automation APROL, B&R Industrial Automation CAN Driver, B&R Industrial Automation CAN Driver CC770, B&R Industrial Automation CAN Driver SJA1000, B&R Industrial Automation Tou0ch Lock, B&R Industrial Automation B&R Single-Touch Driver, B&R Industrial Automation Serial User Mode Touch Driver, B&R Industrial Automation Windows Settings Changer (LTSC), B&R Industrial Automation Windows Settings Changer (2019 LTSC), B&R Industrial Automation Windows 10 Recovery Solution, B&R Industrial Automation ADI driver universal, B&R Industrial Automation ADI Development Kit, B&R Industrial Automation ADI .NET SDK, B&R Industrial Automation SRAM driver, B&R Industrial Automation HMI Service Center, B&R Industrial Automation HMI Service Center Maintenance, B&R Industrial Automation Windows 10 IoT Enterprise 2019 LTSC, B&R Industrial Automation KCF Editor could allow an authenticated local attacker to execute malicious code by placing specially crafted files in the loading search path..This issue affects Scene Viewer: before 4.4.0; Automation Runtime: before J4.93; mapp Vision: before 5.26.1; mapp View: before 5.24.2; mapp Cockpit: before 5.24.2; mapp Safety: before 5.24.2; VC4: before 4.73.2; APROL: before 4.4-01; CAN Driver: before 1.1.0; CAN Driver CC770: before 3.3.0; CAN Driver SJA1000: before 1.3.0; Tou0ch Lock: before 2.1.0; B&R Single-Touch Driver: before 2.0.0; Serial User Mode Touch Driver: before 1.7.1; Windows Settings Changer (LTSC): before 3.2.0; Windows Settings Changer (2019 LTSC): before 2.2.0; Windows 10 Recovery Solution: before 3.2.0; ADI driver universal: before 3.2.0; ADI Development Kit: before 5.5.0; ADI .NET SDK: before 4.1.0; SRAM driver: before 1.2.0; HMI Service Center: before 3.1.0; HMI Service Center Maintenance: before 2.1.0; Windows 10 IoT Enterprise 2019 LTSC: through 1.1; KCF Editor: before 1.1.0. | ||||
CVE-2022-43762 | 1 Br-automation | 1 Industrial Automation Aprol | 2025-03-25 | 7.5 High |
Lack of verification in B&R APROL Tbase server versions < R 4.2-07 may lead to memory leaks when receiving messages | ||||
CVE-2022-43763 | 1 Br-automation | 1 Industrial Automation Aprol | 2025-03-25 | 7.5 High |
Insufficient check of preconditions could lead to Denial of Service conditions when calling commands on the Tbase server of B&R APROL versions < R 4.2-07. | ||||
CVE-2022-43764 | 1 Br-automation | 1 Industrial Automation Aprol | 2025-03-25 | 9.8 Critical |
Insufficient validation of input parameters when changing configuration on Tbase server in B&R APROL versions < R 4.2-07 could result in buffer overflow. This may lead to Denial-of-Service conditions or execution of arbitrary code. | ||||
CVE-2022-43765 | 1 Br-automation | 1 Industrial Automation Aprol | 2025-03-25 | 7.5 High |
B&R APROL versions < R 4.2-07 doesn’t process correctly specially formatted data packages sent to port 55502/tcp, which may allow a network based attacker to cause an application Denial-of-Service. | ||||
CVE-2022-43761 | 1 Br-automation | 1 Industrial Automation Aprol | 2025-03-25 | 9.4 Critical |
Missing authentication when creating and managing the B&R APROL database in versions < R 4.2-07 allows reading and changing the system configuration. | ||||
CVE-2022-4286 | 1 Br-automation | 1 Automation Runtime | 2025-03-20 | 6.1 Medium |
A reflected cross-site scripting (XSS) vulnerability exists in System Diagnostics Manager of B&R Automation Runtime versions >=3.00 and <=C4.93 that enables a remote attacker to execute arbitrary JavaScript in the context of the users browser session. | ||||
CVE-2023-1617 | 1 Br-automation | 1 Vc4 | 2025-02-06 | 9.8 Critical |
Improper Authentication vulnerability in B&R Industrial Automation B&R VC4 (VNC-Server modules). This vulnerability may allow an unauthenticated network-based attacker to bypass the authentication mechanism of the VC4 visualization on affected devices. The impact of this vulnerability depends on the functionality provided in the visualization. This issue affects B&R VC4: from 3.* through 3.96.7, from 4.0* through 4.06.7, from 4.1* through 4.16.3, from 4.2* through 4.26.8, from 4.3* through 4.34.6, from 4.4* through 4.45.1, from 4.5* through 4.45.3, from 4.7* through 4.72.9. | ||||
CVE-2024-0323 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 9.8 Critical |
The FTP server used on the B&R Automation Runtime supports unsecure encryption mechanisms, such as SSLv3, TLSv1.0 and TLS1.1. An network-based attacker can exploit the flaws to conduct man-in-the-middle attacks or to decrypt communications between the affected product clients. | ||||
CVE-2024-0220 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 8.3 High |
B&R Automation Studio Upgrade Service and B&R Technology Guarding use insufficient cryptography for communication to the upgrade and the licensing servers. A network-based attacker could exploit the vulnerability to execute arbitrary code on the products or sniff sensitive data. | ||||
CVE-2023-6028 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 6.1 Medium |
A reflected cross-site scripting (XSS) vulnerability exists in the SVG version of System Diagnostics Manager of B&R Automation Runtime versions <= G4.93 that enables a remote attacker to execute arbitrary JavaScript code in the context of the attacked user’s browser session. | ||||
CVE-2023-3242 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 8.6 High |
Improper initialization implementation in Portmapper used in B&R Industrial Automation Automation Runtime <G4.93 allows unauthenticated network-based attackers to cause permanent denial-of-service conditions. | ||||
CVE-2021-22289 | 1 Br-automation | 1 Studio | 2024-11-21 | 8.3 High |
Improper Input Validation vulnerability in the project upload mechanism in B&R Automation Studio version >=4.0 may allow an unauthenticated network attacker to execute code. | ||||
CVE-2021-22282 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 8.3 High |
Improper Control of Generation of Code ('Code Injection') vulnerability in B&R Industrial Automation Automation Studio allows Local Execution of Code.This issue affects Automation Studio: from 4.0 through 4.12. | ||||
CVE-2021-22281 | 1 Br-automation | 1 Automation Studio | 2024-11-21 | 6.3 Medium |
: Relative Path Traversal vulnerability in B&R Industrial Automation Automation Studio allows Relative Path Traversal.This issue affects Automation Studio: from 4.0 through 4.12. | ||||
CVE-2021-22275 | 1 Br-automation | 1 Automation Runtime | 2024-11-21 | 8.6 High |
Buffer Overflow vulnerability in B&R Automation Runtime webserver allows an unauthenticated network-based attacker to stop the cyclic program on the device and cause a denial of service. | ||||
CVE-2020-24682 | 2 Br-automation, Microsoft | 3 Automation Net\/pvi, Automation Studio, Windows | 2024-11-21 | 7.2 High |
Unquoted Search Path or Element vulnerability in B&R Industrial Automation Automation Studio, B&R Industrial Automation NET/PVI allows Target Programs with Elevated Privileges.This issue affects Automation Studio: from 4.0 through 4.6, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP; NET/PVI: from 4.0 through 4.6, from 4.7.0 before 4.7.7, from 4.8.0 before 4.8.6, from 4.9.0 before 4.9.4. | ||||
CVE-2020-24681 | 2 Br-automation, Microsoft | 2 Automation Studio, Windows | 2024-11-21 | 8.2 High |
Incorrect Permission Assignment for Critical Resource vulnerability in B&R Industrial Automation Automation Studio allows Privilege Escalation.This issue affects Automation Studio: from 4.6.0 through 4.6.X, from 4.7.0 before 4.7.7 SP, from 4.8.0 before 4.8.6 SP, from 4.9.0 before 4.9.4 SP. | ||||
CVE-2020-11646 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 4.3 Medium |
A log information disclosure vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to view log information reserved for other users. | ||||
CVE-2020-11645 | 1 Br-automation | 6 Gatemanager 4260, Gatemanager 4260 Firmware, Gatemanager 8250 and 3 more | 2024-11-21 | 6.5 Medium |
A denial of service vulnerability in B&R GateManager 4260 and 9250 versions <9.0.20262 and GateManager 8250 versions <9.2.620236042 allows authenticated users to limit availability of GateManager instances. |