Filtered by vendor Siemens Subscriptions
Filtered by product Sinec-nms Subscriptions
Total 6 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-40735 1 Siemens 1 Sinec-nms 2025-07-08 8.8 High
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected devices are vulnerable to SQL injection. This could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database.
CVE-2025-40736 1 Siemens 1 Sinec-nms 2025-07-08 9.8 Critical
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application exposes an endpoint that allows an unauthorized modification of administrative credentials. This could allow an unauthenticated attacker to reset the superadmin password and gain full control of the application (ZDI-CAN-26569).
CVE-2025-40737 1 Siemens 1 Sinec-nms 2025-07-08 8.8 High
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26571).
CVE-2025-40738 1 Siemens 1 Sinec-nms 2025-07-08 8.8 High
A vulnerability has been identified in SINEC NMS (All versions < V4.0). The affected application does not properly validate file paths when extracting uploaded ZIP files. This could allow an attacker to write arbitrary files to restricted locations and potentially execute code with elevated privileges (ZDI-CAN-26572).
CVE-2024-31978 1 Siemens 1 Sinec-nms 2024-11-21 7.6 High
A vulnerability has been identified in SINEC NMS (All versions < V2.0 SP2). Affected devices allow authenticated users to export monitoring data. The corresponding API endpoint is susceptible to path traversal and could allow an authenticated attacker to download files from the file system. Under certain circumstances the downloaded files are deleted from the file system.
CVE-2019-6575 1 Siemens 43 Opc Unified Architecture, Simatic Cp443-1 Opc Ua, Simatic Cp443-1 Opc Ua Firmware and 40 more 2024-11-21 7.5 High
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.