Filtered by vendor Siemens Subscriptions
Total 2224 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2012-1800 1 Siemens 4 Scalance S602, Scalance S612, Scalance S613 and 1 more 2025-04-11 N/A
Stack-based buffer overflow in the Profinet DCP protocol implementation on the Siemens Scalance S Security Module firewall S602 V2, S612 V2, and S613 V2 with firmware before 2.3.0.3 allows remote attackers to cause a denial of service (device outage) or possibly execute arbitrary code via a crafted DCP frame.
CVE-2012-2597 1 Siemens 1 Wincc 2025-04-11 N/A
Multiple directory traversal vulnerabilities in Siemens WinCC 7.0 SP3 before Update 2 allow remote authenticated users to read arbitrary files via a crafted parameter in a URL.
CVE-2011-4530 1 Siemens 1 Automation License Manager 2025-04-11 N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 does not properly copy fields obtained from clients, which allows remote attackers to cause a denial of service (exception and daemon crash) via long fields, as demonstrated by fields to the (1) open_session->workstation->NAME or (2) grant->VERSION function.
CVE-2012-3003 1 Siemens 1 Wincc 2025-04-11 N/A
Open redirect vulnerability in an unspecified web application in Siemens WinCC 7.0 SP3 before Update 2 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks via a URL in a GET request.
CVE-2012-2596 1 Siemens 1 Wincc 2025-04-11 N/A
The XPath functionality in unspecified web applications in Siemens WinCC 7.0 SP3 before Update 2 does not properly handle special characters in parameters, which allows remote authenticated users to read or modify settings via a crafted URL, related to an "XML injection" attack.
CVE-2012-1803 1 Siemens 1 Ruggedcom Rugged Operating System 2025-04-11 N/A
RuggedCom Rugged Operating System (ROS) 3.10.x and earlier has a factory account with a password derived from the MAC Address field in the banner, which makes it easier for remote attackers to obtain access by performing a calculation on this address value, and then establishing a (1) TELNET, (2) remote shell (aka rsh), or (3) serial-console session.
CVE-2011-4876 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
Directory traversal vulnerability in HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to execute, read, create, modify, or delete arbitrary files via a .. (dot dot) in a string.
CVE-2011-4531 1 Siemens 1 Automation License Manager 2025-04-11 N/A
Siemens Automation License Manager (ALM) 4.0 through 5.1+SP1+Upd1 allows remote attackers to cause a denial of service (NULL pointer dereference and daemon crash) via crafted content in a (1) get_target_ocx_param or (2) send_target_ocx_param command.
CVE-2013-2780 1 Siemens 18 Simatic S7-1200, Simatic S7-1200 Cpu 1211c, Simatic S7-1200 Cpu 1211c Firmware and 15 more 2025-04-11 N/A
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
CVE-2011-4877 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
HmiLoad in the runtime loader in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime, when Transfer Mode is enabled, allows remote attackers to cause a denial of service (application crash) by sending crafted data over TCP.
CVE-2011-4056 1 Siemens 1 Tecnomatix Factorylink 2025-04-11 N/A
An unspecified ActiveX control in ActBar.ocx in Siemens Tecnomatix FactoryLink 6.6.1 (aka 6.6 SP1), 7.5.217 (aka 7.5 SP2), and 8.0.2.54 allows remote attackers to create or overwrite arbitrary files via the save method.
CVE-2014-1966 1 Siemens 3 Ruggedcom Rs950g, Ruggedcom Rsg2488, Ruggedcom Rugged Operating System 2025-04-11 N/A
The SNMP implementation in Siemens RuggedCom ROS before 3.11, ROS 3.11 for RS950G, ROS 3.12 before 3.12.4, and ROS 4.0 for RSG2488 allows remote attackers to cause a denial of service (device outage) via crafted packets.
CVE-2011-4532 1 Siemens 1 Automation License Manager 2025-04-11 N/A
Absolute path traversal vulnerability in the ALMListView.ALMListCtrl ActiveX control in almaxcx.dll in the graphical user interface in Siemens Automation License Manager (ALM) 2.0 through 5.1+SP1+Upd2 allows remote attackers to overwrite arbitrary files via the Save method.
CVE-2013-5944 1 Siemens 3 Scalance X-200, Scalance X-200 Series Firmware, Scalance X-200irt 2025-04-11 N/A
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.
CVE-2012-5409 1 Siemens 1 Sipass Integrated 2025-04-11 N/A
AscoServer.exe in the server in Siemens SiPass integrated MP2.6 and earlier does not properly handle IOCP RPC messages received over an Ethernet network, which allows remote attackers to write data to any memory location and consequently execute arbitrary code via crafted messages, as demonstrated by an arbitrary pointer dereference attack or a buffer overflow attack.
CVE-2013-6920 1 Siemens 14 Sinamics G110, Sinamics G110d, Sinamics G120 and 11 more 2025-04-11 N/A
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.
CVE-2012-4693 2 Invensys, Siemens 2 Wonderware Intouch, Processsuite 2025-04-11 N/A
Invensys Wonderware InTouch 2012 R2 and earlier and Siemens ProcessSuite use a weak encryption algorithm for data in Ps_security.ini, which makes it easier for local users to discover passwords by reading this file.
CVE-2011-4509 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
The HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime has an improperly selected default password for the administrator account, which makes it easier for remote attackers to obtain access via a brute-force approach involving many HTTP requests.
CVE-2012-1802 1 Siemens 10 Scalance X-300, Scalance X-300 Firmware, Scalance X-300eec and 7 more 2025-04-11 N/A
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.
CVE-2011-4514 1 Siemens 5 Simatic Hmi Panels, Wincc, Wincc Flexible and 2 more 2025-04-11 N/A
The TELNET daemon in Siemens WinCC flexible 2004, 2005, 2007, and 2008; WinCC V11 (aka TIA portal); the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime does not perform authentication, which makes it easier for remote attackers to obtain access via a TCP session.