Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"state": "PUBLISHED", "cveId": "CVE-2024-32288", "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "assignerShortName": "mitre", "dateUpdated": "2024-08-02T02:06:44.063Z", "dateReserved": "2024-04-12T00:00:00", "datePublished": "2024-04-17T00:00:00"}, "containers": {"cna": {"providerMetadata": {"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca", "shortName": "mitre", "dateUpdated": "2024-04-17T14:05:41.800227"}, "descriptions": [{"lang": "en", "value": "Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function."}], "affected": [{"vendor": "n/a", "product": "n/a", "versions": [{"version": "n/a", "status": "affected"}]}], "references": [{"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromwebExcptypemanFilter.md"}], "problemTypes": [{"descriptions": [{"type": "text", "lang": "en", "description": "n/a"}]}]}, "adp": [{"problemTypes": [{"descriptions": [{"type": "CWE", "cweId": "CWE-121", "lang": "en", "description": "CWE-121 Stack-based Buffer Overflow"}]}], "affected": [{"vendor": "tenda", "product": "w30e", "cpes": ["cpe:2.3:h:tenda:w30e:-:*:*:*:*:*:*:*"], "defaultStatus": "unknown", "versions": [{"version": "v1.0", "status": "affected", "lessThanOrEqual": "v1.01.1.25(633)", "versionType": "custom"}]}], "metrics": [{"cvssV3_1": {"scope": "UNCHANGED", "version": "3.1", "baseScore": 6.3, "attackVector": "NETWORK", "baseSeverity": "MEDIUM", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L", "integrityImpact": "LOW", "userInteraction": "NONE", "attackComplexity": "LOW", "availabilityImpact": "LOW", "privilegesRequired": "LOW", "confidentialityImpact": "LOW"}}, {"other": {"type": "ssvc", "content": {"timestamp": "2024-07-16T18:40:59.765576Z", "id": "CVE-2024-32288", "options": [{"Exploitation": "poc"}, {"Automatable": "no"}, {"Technical Impact": "partial"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2024-07-16T18:44:16.245Z"}}, {"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-02T02:06:44.063Z"}, "title": "CVE Program Container", "references": [{"url": "https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W30E/fromwebExcptypemanFilter.md", "tags": ["x_transferred"]}]}]}}