Show plain JSON{"dataType": "CVE_RECORD", "dataVersion": "5.1", "cveMetadata": {"state": "PUBLISHED", "cveId": "CVE-2022-2069", "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "assignerShortName": "icscert", "dateUpdated": "2025-04-16T17:46:09.746Z", "dateReserved": "2022-06-13T00:00:00.000Z", "datePublished": "2022-10-20T00:00:00.000Z"}, "containers": {"cna": {"title": " Datalogics APDFL library Heap-based Buffer Overflow", "providerMetadata": {"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6", "shortName": "icscert", "dateUpdated": "2022-10-20T00:00:00.000Z"}, "descriptions": [{"lang": "en", "value": "The APDFL.dll in Siemens JT2Go prior to V13.3.0.5 and Siemens Teamcenter Visualization prior to V14.0.0.2 contains an out of bounds write past the fixed-length heap-based buffer while parsing specially crafted PDF files. This could allow an attacker to execute code in the context of the current process."}], "affected": [{"vendor": "Siemens", "product": "JT2Go", "versions": [{"version": "unspecified", "lessThan": "V13.3.0.5", "status": "affected", "versionType": "custom"}]}, {"vendor": "Siemens", "product": "Teamcenter Visualization V13.3", "versions": [{"version": "unspecified", "lessThan": "V13.3.0.5", "status": "affected", "versionType": "custom"}]}, {"vendor": "Siemens", "product": "Teamcenter Visualization V14.0", "versions": [{"version": "unspecified", "lessThan": "V14.0.0.2", "status": "affected", "versionType": "custom"}]}], "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdf"}, {"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07"}], "credits": [{"lang": "en", "value": "Siemens reported this vulnerability to CISA."}], "metrics": [{"cvssV3_1": {"version": "3.1", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "attackVector": "LOCAL", "attackComplexity": "LOW", "privilegesRequired": "NONE", "userInteraction": "REQUIRED", "scope": "UNCHANGED", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH"}}], "problemTypes": [{"descriptions": [{"type": "CWE", "lang": "en", "description": " CWE-122: Heap-based Buffer Overflow", "cweId": "CWE-122"}]}], "x_generator": {"engine": "Vulnogram 0.0.9"}, "source": {"discovery": "INTERNAL"}, "workarounds": [{"lang": "en", "value": "Avoid opening untrusted files in JT2Go and Teamcenter Visualization\n\nAs a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens\u2019 and to follow the recommendations in the product manuals.\n\nAdditional information on industrial security by Siemens can be found on Siemens\u2019 Industrial Security webpage.\n\nFor more information see Siemens Security Advisory SSA-829738"}], "solutions": [{"lang": "en", "value": "Siemens recommends updating to the latest version:\nTeamcenter Visualization V13.3: Update to version 13.3.0.5 or later\nTeamcenter Visualization V14.0: Currently no fix available.\nJT2Go V13.3.0.5: Update to version 13.3.0.5 or later\n\nFor more information see Siemens Security Advisory SSA-829738"}]}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T00:24:44.192Z"}, "title": "CVE Program Container", "references": [{"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-829738.pdf", "tags": ["x_transferred"]}, {"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-195-07", "tags": ["x_transferred"]}]}, {"metrics": [{"other": {"type": "ssvc", "content": {"timestamp": "2025-04-16T17:26:54.288511Z", "id": "CVE-2022-2069", "options": [{"Exploitation": "none"}, {"Automatable": "no"}, {"Technical Impact": "total"}], "role": "CISA Coordinator", "version": "2.0.3"}}}], "title": "CISA ADP Vulnrichment", "providerMetadata": {"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP", "dateUpdated": "2025-04-16T17:46:09.746Z"}}]}}