Show plain JSON{"configurations": [{"nodes": [{"cpeMatch": [{"criteria": "cpe:2.3:o:tendacn:ac10_firmware:15.03.06.23:*:*:*:*:*:*:*", "matchCriteriaId": "C7952445-9298-49B5-9F77-DEF7B18C9483", "vulnerable": true}], "negate": false, "operator": "OR"}, {"cpeMatch": [{"criteria": "cpe:2.3:h:tendacn:ac10:-:*:*:*:*:*:*:*", "matchCriteriaId": "0FE0DA72-D225-4BAE-8813-816AB8F0B3FB", "vulnerable": false}], "negate": false, "operator": "OR"}], "operator": "AND"}], "descriptions": [{"lang": "en", "value": "Tenda AC10-1200 v15.03.06.23_EN was discovered to contain a buffer overflow via the list parameter in the fromSetIpMacBind function."}, {"lang": "es", "value": "Se ha detectado que Tenda AC10-1200 versi\u00f3n v15.03.06.23_ES, conten\u00eda un desbordamiento de b\u00fafer por medio del par\u00e1metro list en la funci\u00f3n fromSetIpMacBind"}], "id": "CVE-2021-38772", "lastModified": "2024-11-21T06:18:02.840", "metrics": {"cvssMetricV2": [{"acInsufInfo": false, "baseSeverity": "HIGH", "cvssData": {"accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "integrityImpact": "NONE", "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0"}, "exploitabilityScore": 10.0, "impactScore": 6.9, "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "source": "nvd@nist.gov", "type": "Primary", "userInteractionRequired": false}], "cvssMetricV31": [{"cvssData": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}, "exploitabilityScore": 3.9, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary"}]}, "published": "2022-03-23T19:15:07.873", "references": [{"source": "cve@mitre.org", "tags": ["Exploit", "Vendor Advisory"], "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-3-yet-another-buffer-overflow-4eb322f64823"}, {"source": "af854a3a-2127-422b-91ae-364da2661108", "tags": ["Exploit", "Vendor Advisory"], "url": "https://noob3xploiter.medium.com/hacking-the-tenda-ac10-1200-router-part-3-yet-another-buffer-overflow-4eb322f64823"}], "sourceIdentifier": "cve@mitre.org", "vulnStatus": "Modified", "weaknesses": [{"description": [{"lang": "en", "value": "CWE-120"}], "source": "nvd@nist.gov", "type": "Primary"}]}