Show plain JSON{"containers": {"cna": {"affected": [{"product": "800xA, Control Software for AC 800M", "vendor": "ABB", "versions": [{"lessThan": "unspecified", "status": "affected", "version": "5.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "5.1.1-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.1-4", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.0.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.0.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.1.1-1", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "Control Builder Safe", "vendor": "ABB", "versions": [{"status": "affected", "version": "1.x"}, {"status": "affected", "version": "2.0"}, {"status": "affected", "version": "3.0"}]}, {"product": "Compact Product Suite - Control and I/O", "vendor": "ABB", "versions": [{"lessThan": "unspecified", "status": "affected", "version": "5.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "5.1.1-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.1-4", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.0.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.0.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.1.1-1", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "ABB Base Software for SoftControl", "vendor": "ABB", "versions": [{"lessThan": "unspecified", "status": "affected", "version": "5.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "5.1.1-0", "versionType": "custom"}, {"lessThanOrEqual": "5.1.1-4", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.0.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.0.0-3", "status": "affected", "version": "unspecified", "versionType": "custom"}, {"lessThan": "unspecified", "status": "affected", "version": "6.1.0-0", "versionType": "custom"}, {"lessThanOrEqual": "6.1.1-1", "status": "affected", "version": "unspecified", "versionType": "custom"}]}], "credits": [{"lang": "en", "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."}], "datePublic": "2022-02-17T00:00:00", "descriptions": [{"lang": "en", "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2022-04-01T22:17:43", "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "shortName": "ABB"}, "references": [{"tags": ["x_refsource_MISC"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499&LanguageCode=en&DocumentPartId=&Action=Launch"}], "source": {"discovery": "UNKNOWN"}, "title": "AC 800M MMS - Denial of Service vulnerability in MMS communication", "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "cybersecurity@ch.abb.com", "DATE_PUBLIC": "2022-02-17T10:33:00.000Z", "ID": "CVE-2021-22277", "STATE": "PUBLIC", "TITLE": "AC 800M MMS - Denial of Service vulnerability in MMS communication"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "800xA, Control Software for AC 800M", "version": {"version_data": [{"version_affected": ">=", "version_value": "5.1.0-0"}, {"version_affected": "<=", "version_value": "5.1.0-3"}, {"version_affected": ">=", "version_value": "5.1.1-0"}, {"version_affected": "<=", "version_value": "5.1.1-4"}, {"version_affected": ">=", "version_value": "6.0.0-0"}, {"version_affected": "<=", "version_value": "6.0.0-3"}, {"version_affected": ">=", "version_value": "6.1.0-0"}, {"version_affected": "<=", "version_value": "6.1.1-1"}]}}, {"product_name": "Control Builder Safe", "version": {"version_data": [{"version_affected": "=", "version_value": "1.x"}, {"version_affected": "=", "version_value": "2.0"}, {"version_affected": "=", "version_value": "3.0"}]}}, {"product_name": "Compact Product Suite - Control and I/O", "version": {"version_data": [{"version_affected": ">=", "version_value": "5.1.0-0"}, {"version_affected": "<=", "version_value": "5.1.0-3"}, {"version_affected": ">=", "version_value": "5.1.1-0"}, {"version_affected": "<=", "version_value": "5.1.1-4"}, {"version_affected": ">=", "version_value": "6.0.0-0"}, {"version_affected": "<=", "version_value": "6.0.0-3"}, {"version_affected": ">=", "version_value": "6.1.0-0"}, {"version_affected": "<=", "version_value": "6.1.1-1"}]}}, {"product_name": "ABB Base Software for SoftControl", "version": {"version_data": [{"version_affected": ">=", "version_value": "5.1.0-0"}, {"version_affected": "<=", "version_value": "5.1.0-3"}, {"version_affected": ">=", "version_value": "5.1.1-0"}, {"version_affected": "<=", "version_value": "5.1.1-4"}, {"version_affected": ">=", "version_value": "6.0.0-0"}, {"version_affected": "<=", "version_value": "6.0.0-3"}, {"version_affected": ">=", "version_value": "6.1.0-0"}, {"version_affected": "<=", "version_value": "6.1.1-1"}]}}]}, "vendor_name": "ABB"}]}}, "credit": [{"lang": "eng", "value": "ABB thanks the Industrial Control Security Laboratory of Qi An Xin Technology Group Inc. in China for helping to identify the vulnerabilities and protecting our customers."}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-20 Improper Input Validation"}]}]}, "references": {"reference_data": [{"name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499&LanguageCode=en&DocumentPartId=&Action=Launch", "refsource": "MISC", "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499&LanguageCode=en&DocumentPartId=&Action=Launch"}]}, "source": {"discovery": "UNKNOWN"}}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T18:37:18.475Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_MISC", "x_transferred"], "url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001499&LanguageCode=en&DocumentPartId=&Action=Launch"}]}]}, "cveMetadata": {"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9", "assignerShortName": "ABB", "cveId": "CVE-2021-22277", "datePublished": "2022-04-01T22:17:43.044264Z", "dateReserved": "2021-01-05T00:00:00", "dateUpdated": "2024-09-17T01:41:41.993Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}