Show plain JSON{"containers": {"cna": {"affected": [{"product": "0852-0303", "vendor": "WAGO", "versions": [{"lessThanOrEqual": "V1.2.3.S0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "0852-1305", "vendor": "WAGO", "versions": [{"lessThanOrEqual": "V1.1.7.S0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "0852-1505", "vendor": "WAGO", "versions": [{"lessThanOrEqual": "V1.1.6.S0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "0852-1305/000-001", "vendor": "WAGO", "versions": [{"lessThanOrEqual": "V1.0.4.S0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}, {"product": "0852-1505/000-001", "vendor": "WAGO", "versions": [{"lessThanOrEqual": "V1.0.4.S0", "status": "affected", "version": "unspecified", "versionType": "custom"}]}], "credits": [{"lang": "en", "value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"}], "datePublic": "2021-05-05T00:00:00", "descriptions": [{"lang": "en", "value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."}], "metrics": [{"cvssV3_1": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}], "problemTypes": [{"descriptions": [{"cweId": "CWE-306", "description": "CWE-306 Missing Authentication for Critical Function", "lang": "en", "type": "CWE"}]}], "providerMetadata": {"dateUpdated": "2021-05-13T13:45:25", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE"}, "references": [{"tags": ["x_refsource_CONFIRM"], "url": "https://cert.vde.com/en-us/advisories/vde-2021-013"}], "solutions": [{"lang": "en", "value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW < 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW >=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"}], "source": {"advisory": "VDE-2021-013", "defect": ["VDE-2021-013"], "discovery": "EXTERNAL"}, "title": "WAGO: Managed Switches: Unauthorized creation of user accounts", "workarounds": [{"lang": "en", "value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."}], "x_generator": {"engine": "Vulnogram 0.0.9"}, "x_legacyV4Record": {"CVE_data_meta": {"ASSIGNER": "info@cert.vde.com", "DATE_PUBLIC": "2021-05-05T10:00:00.000Z", "ID": "CVE-2021-20998", "STATE": "PUBLIC", "TITLE": "WAGO: Managed Switches: Unauthorized creation of user accounts"}, "affects": {"vendor": {"vendor_data": [{"product": {"product_data": [{"product_name": "0852-0303", "version": {"version_data": [{"version_affected": "<=", "version_value": "V1.2.3.S0"}]}}, {"product_name": "0852-1305", "version": {"version_data": [{"version_affected": "<=", "version_value": "V1.1.7.S0"}]}}, {"product_name": "0852-1505", "version": {"version_data": [{"version_affected": "<=", "version_value": "V1.1.6.S0"}]}}, {"product_name": "0852-1305/000-001", "version": {"version_data": [{"version_affected": "<=", "version_value": "V1.0.4.S0"}]}}, {"product_name": "0852-1505/000-001", "version": {"version_data": [{"version_affected": "<=", "version_value": "V1.0.4.S0"}]}}]}, "vendor_name": "WAGO"}]}}, "credit": [{"lang": "eng", "value": "Dr. Tobias Augustin and Stephan Tigges of IKS \u2013 Institut f\u00fcr Kooperative Systeme GmbH, Kai Gaul and Jan R\u00fcbenach of ABO Wind AG, coordinated by CERT@VDE"}], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": {"description_data": [{"lang": "eng", "value": "In multiple managed switches by WAGO in different versions without authorization and with specially crafted packets it is possible to create users."}]}, "generator": {"engine": "Vulnogram 0.0.9"}, "impact": {"cvss": {"attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 10, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H", "version": "3.1"}}, "problemtype": {"problemtype_data": [{"description": [{"lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function"}]}]}, "references": {"reference_data": [{"name": "https://cert.vde.com/en-us/advisories/vde-2021-013", "refsource": "CONFIRM", "url": "https://cert.vde.com/en-us/advisories/vde-2021-013"}]}, "solution": [{"lang": "en", "value": "The Web-Based Management is only needed during installation and commissioning, not during normal operations. It is recommended to disable the web server after commissioning. The Command Line Interface (CLI) is an alternative for commissioning the device. This is the easiest and securest way to protect your device from the listed vulnerabilities.\n\nRegardless of the action described above, the vulnerabilities are fixed with following firmware releases:\nItem number [FW version]\n0852-0303 (HW < 3)* [V1.2.5.S0] Detailed information about the hardware version is described in the installation guide.\n0852-0303 (HW >=3)* [V1.2.3.S1] Detailed information about the hardware version is described in the installation guide.\n0852-1305 [V1.1.8.S0]\n0852-1505 [V1.1.7.S0]\n0852-1305/000-001 [V1.1.4.S0]\n0852-1505/000-001 [V1.1.4.S0]"}], "source": {"advisory": "VDE-2021-013", "defect": ["VDE-2021-013"], "discovery": "EXTERNAL"}, "work_around": [{"lang": "en", "value": "Disable the web server of the device.\nUse the CLI interface of the device.\nUpdate to the latest firmware.\nRestrict network access to the device.\nDo not directly connect the device to the internet."}]}}, "adp": [{"providerMetadata": {"orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE", "dateUpdated": "2024-08-03T17:53:23.122Z"}, "title": "CVE Program Container", "references": [{"tags": ["x_refsource_CONFIRM", "x_transferred"], "url": "https://cert.vde.com/en-us/advisories/vde-2021-013"}]}]}, "cveMetadata": {"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2021-20998", "datePublished": "2021-05-13T13:45:25.179394Z", "dateReserved": "2020-12-17T00:00:00", "dateUpdated": "2024-09-17T00:51:42.120Z", "state": "PUBLISHED"}, "dataType": "CVE_RECORD", "dataVersion": "5.1"}