These Sinapsi devices do not check for special elements in commands sent to the system. By accessing certain pages with administrative privileges that do not require authentication within the device, attackers can execute arbitrary, unexpected, or dangerous commands directly onto the operating system.
History

Tue, 08 Jul 2025 15:30:00 +0000

Type Values Removed Values Added
Description ping.php on the Sinapsi eSolar Light Photovoltaic System Monitor (aka Schneider Electric Ezylog photovoltaic SCADA management server), Sinapsi eSolar, and Sinapsi eSolar DUO with firmware before 2.0.2870_2.2.12 allows remote attackers to execute arbitrary commands via shell metacharacters in the ip_dominio parameter. These Sinapsi devices do not check for special elements in commands sent to the system. By accessing certain pages with administrative privileges that do not require authentication within the device, attackers can execute arbitrary, unexpected, or dangerous commands directly onto the operating system.
Title Sinapsi eSolar OS Command Injection
Weaknesses CWE-78
References

cve-icon MITRE

Status: PUBLISHED

Assigner: icscert

Published: 2012-11-23T11:00:00

Updated: 2025-07-08T15:25:08.554Z

Reserved: 2012-11-14T00:00:00

Link: CVE-2012-5863

cve-icon Vulnrichment

No data.

cve-icon NVD

Status : Deferred

Published: 2012-11-23T12:09:58.477

Modified: 2025-07-08T16:15:26.747

Link: CVE-2012-5863

cve-icon Redhat

No data.