Filtered by vendor Tenda
Subscriptions
Filtered by product Ac7
Subscriptions
Total
55 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2018-14558 | 1 Tenda | 6 Ac10, Ac10 Firmware, Ac7 and 3 more | 2025-07-30 | 9.8 Critical |
An issue was discovered on Tenda AC7 devices with firmware through V15.03.06.44_CN(AC7), AC9 devices with firmware through V15.03.05.19(6318)_CN(AC9), and AC10 devices with firmware through V15.03.06.23_CN(AC10). A command Injection vulnerability allows attackers to execute arbitrary OS commands via a crafted goform/setUsbUnload request. This occurs because the "formsetUsbUnload" function executes a dosystemCmd function with untrusted input. | ||||
CVE-2025-8017 | 1 Tenda | 1 Ac7 | 2025-07-25 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-1819 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-07-16 | 6.3 Medium |
A vulnerability, which was classified as critical, was found in Tenda AC7 1200M 15.03.06.44. Affected is the function TendaTelnet of the file /goform/telnet. The manipulation of the argument lan_ip leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-5861 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-06-09 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-5862 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-06-09 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-3346 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-05-27 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-4810 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-05-24 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-4809 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-05-24 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-2899 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-04-10 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetWirelessRepeat of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-257942 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2025-1851 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-04-10 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC7 up to 15.03.06.44. This affects the function formSetFirewallCfg of the file /goform/SetFirewallCfg. The manipulation of the argument firewallEn leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-29137 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-04-01 | 9.8 Critical |
Tenda AC7 V1.0 V15.03.06.44 found a buffer overflow caused by the timeZone parameter in the form_fast_setting_wifi_set function, which can cause RCE. | ||||
CVE-2025-29135 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-04-01 | 9.8 Critical |
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function. | ||||
CVE-2024-48826 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | 8 High |
Tenda AC7 v.15.03.06.44 ate_iwpriv_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | ||||
CVE-2024-48825 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | 8 High |
Tenda AC7 v.15.03.06.44 ate_ifconfig_set has pre-authentication command injection allowing remote attackers to execute arbitrary code. | ||||
CVE-2024-32301 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AC7V1.0 v15.03.06.44 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | ||||
CVE-2024-32281 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-03-17 | 8.8 High |
Tenda AC7V1.0 v15.03.06.44 firmware contains a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | ||||
CVE-2024-2892 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this vulnerability is the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-257935. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2893 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. Affected by this issue is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257936. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2894 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. This affects the function formSetQosBand of the file /goform/SetNetControlList. The manipulation of the argument list leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257937 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-2895 | 1 Tenda | 2 Ac7, Ac7 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. This vulnerability affects the function formWifiWpsOOB of the file /goform/WifiWpsOOB. The manipulation of the argument index leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-257938 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |