Filtered by CWE-665
Total 424 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2023-0397 1 Zephyrproject 1 Zephyr 2025-04-03 9.6 Critical
A malicious / defect bluetooth controller can cause a Denial of Service due to unchecked input in le_read_buffer_size_complete.
CVE-2001-1471 1 Phpbb 1 Phpbb 2025-04-03 8.8 High
prefs.php in phpBB 1.4.0 and earlier allows remote authenticated users to execute arbitrary PHP code via an invalid language value, which prevents the variables (1) $l_statsblock in prefs.php or (2) $l_privnotify in auth.php from being properly initialized, which can be modified by the user and later used in an eval statement.
CVE-1999-0993 1 Microsoft 1 Exchange Server 2025-04-03 N/A
Modifications to ACLs (Access Control Lists) in Microsoft Exchange 5.5 do not take effect until the directory store cache is refreshed.
CVE-2024-28084 2 Fedoraproject, Intel 2 Fedora, Inet Wireless Daemon 2025-03-27 7.5 High
p2putil.c in iNet wireless daemon (IWD) through 2.15 allows attackers to cause a denial of service (daemon crash) or possibly have unspecified other impact because of initialization issues in situations where parsing of advertised service information fails.
CVE-2023-23555 1 F5 13 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 10 more 2025-03-26 7.5 High
On BIG-IP Virtual Edition versions 15.1x beginning in 15.1.4 to before 15.1.8 and 14.1.x beginning in 14.1.5 to before 14.1.5.3, and BIG-IP SPK beginning in 1.5.0 to before 1.6.0, when FastL4 profile is configured on a virtual server, undisclosed traffic can cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
CVE-2024-39864 2 Apache, Apache Software Foundation 2 Cloudstack, Apache Cloudstack 2025-03-19 9.8 Critical
The CloudStack integration API service allows running its unauthenticated API server (usually on port 8096 when configured and enabled via integration.api.port global setting) for internal portal integrations and for testing purposes. By default, the integration API service port is disabled and is considered disabled when integration.api.port is set to 0 or negative. Due to an improper initialisation logic, the integration API service would listen on a random port when its port value is set to 0 (default value). An attacker that can access the CloudStack management network could scan and find the randomised integration API service port and exploit it to perform unauthorised administrative actions and perform remote code execution on CloudStack managed hosts and result in complete compromise of the confidentiality, integrity, and availability of CloudStack managed infrastructure. Users are recommended to restrict the network access on the CloudStack management server hosts to only essential ports. Users are recommended to upgrade to version 4.18.2.1, 4.19.0.2 or later, which addresses this issue.
CVE-2023-40261 1 Dieboldnixdorf 1 Vynamic Security Suite 2025-03-13 4.6 Medium
Diebold Nixdorf Vynamic Security Suite (VSS) before 3.3.0 SR17, 4.0.0 SR07, 4.1.0 SR04, 4.2.0 SR04, and 4.3.0 SR02 fails to validate file attributes during the Pre-Boot Authorization (PBA) process. This can be exploited by a physical attacker who is able to manipulate the contents of the system's hard disk.
CVE-2023-20591 1 Amd 132 Epyc 7003 Firmware, Epyc 7203, Epyc 7203 Firmware and 129 more 2025-03-13 6.5 Medium
Improper re-initialization of IOMMU during the DRTM event may permit an untrusted platform configuration to persist, allowing an attacker to read or modify hypervisor memory, potentially resulting in loss of confidentiality, integrity, and availability.
CVE-2021-3329 1 Zephyrproject 1 Zephyr 2025-03-11 9.6 Critical
Lack of proper validation in HCI Host stack initialization can cause a crash of the bluetooth stack
CVE-2023-22466 1 Tokio 1 Tokio 2025-03-10 5.4 Medium
Tokio is a runtime for writing applications with Rust. Starting with version 1.7.0 and prior to versions 1.18.4, 1.20.3, and 1.23.1, when configuring a Windows named pipe server, setting `pipe_mode` will reset `reject_remote_clients` to `false`. If the application has previously configured `reject_remote_clients` to `true`, this effectively undoes the configuration. Remote clients may only access the named pipe if the named pipe's associated path is accessible via a publicly shared folder (SMB). Versions 1.23.1, 1.20.3, and 1.18.4 have been patched. The fix will also be present in all releases starting from version 1.24.0. Named pipes were introduced to Tokio in version 1.7.0, so releases older than 1.7.0 are not affected. As a workaround, ensure that `pipe_mode` is set first after initializing a `ServerOptions`.
CVE-2021-22283 1 Abb 38 Evd4, Evd4 Firmware, Rec615 and 35 more 2025-03-07 6.2 Medium
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2.
CVE-2023-27115 1 Webassembly 1 Webassembly 2025-02-28 5.5 Medium
WebAssembly v1.0.29 was discovered to contain a segmentation fault via the component wabt::cat_compute_size.
CVE-2020-27950 1 Apple 4 Ipados, Iphone Os, Macos and 1 more 2025-02-28 5.5 Medium
A memory initialization issue was addressed. This issue is fixed in macOS Big Sur 11.0.1, watchOS 7.1, iOS 12.4.9, watchOS 6.2.9, Security Update 2020-006 High Sierra, Security Update 2020-006 Mojave, iOS 14.2 and iPadOS 14.2, watchOS 5.3.9, macOS Catalina 10.15.7 Supplemental Update, macOS Catalina 10.15.7 Update. A malicious application may be able to disclose kernel memory.
CVE-2023-40596 2 Microsoft, Splunk 2 Windows, Splunk 2025-02-28 7 High
In Splunk Enterprise versions earlier than 8.2.12, 9.0.6, and 9.1.1, a dynamic link library (DLL) that ships with Splunk Enterprise references an insecure path for the OPENSSLDIR build definition. An attacker can abuse this reference and subsequently install malicious code to achieve privilege escalation on the Windows machine.
CVE-2023-26084 1 Arm 1 Aarch64cryptolib 2025-02-27 3.7 Low
The armv8_dec_aes_gcm_full() API of Arm AArch64cryptolib before 86065c6 fails to the verify the authentication tag of AES-GCM protected data, leading to a man-in-the-middle attack. This occurs because of an improperly initialized variable.
CVE-2023-1513 3 Fedoraproject, Linux, Redhat 3 Fedora, Linux Kernel, Enterprise Linux 2025-02-25 3.3 Low
A flaw was found in KVM. When calling the KVM_GET_DEBUGREGS ioctl, on 32-bit systems, there might be some uninitialized portions of the kvm_debugregs structure that could be copied to userspace, causing an information leak.
CVE-2022-48352 1 Huawei 2 Emui, Harmonyos 2025-02-24 7.5 High
Some smartphones have data initialization issues. Successful exploitation of this vulnerability may cause a system panic.
CVE-2022-27493 1 Intel 4 Lapbc510, Lapbc510 Firmware, Lapbc710 and 1 more 2025-02-18 7.8 High
Improper initialization in the firmware for some Intel(R) NUC Laptop Kits before version BC0076 may allow a privileged user to potentially enable an escalation of privilege via local access.
CVE-2024-26021 2025-02-13 2.3 Low
Improper initialization in the firmware for some Intel(R) AMT and Intel(R) Standard Manageability may allow a privileged user to potentially enable information disclosure via local access.
CVE-2023-5370 1 Freebsd 1 Freebsd 2025-02-13 5.5 Medium
On CPU 0 the check for the SMCCC workaround is called before SMCCC support has been initialized. This resulted in no speculative execution workarounds being installed on CPU 0.