CVE-2019-13533 1 Omron 2 Plc Cj Firmware, Plc Cs Firmware 2024-11-21 8.1 High
In Omron PLC CJ series, all versions, and Omron PLC CS series, all versions, an attacker could monitor traffic between the PLC and the controller and replay requests that could result in the opening and closing of industrial valves.
CVE-2019-12887 1 Keyidentity 1 Linotp 2024-11-21 N/A
KeyIdentity LinOTP before 2.10.5.3 has Incorrect Access Control (issue 1 of 2).
CVE-2019-12393 1 Anviz 1 Management System 2024-11-21 7.5 High
Anviz access control devices are vulnerable to replay attacks which could allow attackers to intercept and replay open door requests.
CVE-2019-11856 1 Sierrawireless 13 Airlink Es440, Airlink Es450, Airlink Gx400 and 10 more 2024-11-21 3.3 Low
A nonce reuse vulnerability exists in the ACEView service of ALEOS before 4.13.0, 4.9.5, and 4.4.9 allowing message replay. Captured traffic to the ACEView service can be replayed to other gateways sharing the same credentials.
CVE-2019-11334 1 Tzumi 3 Klic Lock, Klic Smart Padlock Model 5686, Klic Smart Padlock Model 5686 Firmware 2024-11-21 3.7 Low
An authentication bypass in website post requests in the Tzumi Electronics Klic Lock application 1.0.9 for mobile devices allows attackers to access resources (that are not otherwise accessible without proper authentication) via capture-replay. Physically proximate attackers can use this information to unlock unauthorized Tzumi Electronics Klic Smart Padlock Model 5686 Firmware 6.2.
CVE-2018-7790 1 Schneider-electric 2 Modicon M221, Modicon M221 Firmware 2024-11-21 9.8 Critical
An Information Management Error vulnerability exists in Schneider Electric's Modicon M221 product (all references, all versions prior to firmware V1.6.2.0). The vulnerability allows unauthorized users to replay authentication sequences. If an attacker exploits this vulnerability and connects to a Modicon M221, the attacker can upload the original program from the PLC.
CVE-2018-7356 1 Zte 2 Zxr10 8905e, Zxr10 8905e Firmware 2024-11-21 N/A
All versions up to V3.03.10.B23P2 of ZTE ZXR10 8905E product are impacted by TCP Initial Sequence Number (ISN) reuse vulnerability, which can generate easily predictable ISN, and allows remote attackers to spoof connections.
CVE-2018-1128 3 Debian, Opensuse, Redhat 10 Debian Linux, Leap, Ceph and 7 more 2024-11-21 N/A
It was found that cephx authentication protocol did not verify ceph clients correctly and was vulnerable to replay attack. Any attacker having access to ceph cluster network who is able to sniff packets on network can use this vulnerability to authenticate with ceph service and perform actions allowed by ceph service. Ceph branches master, mimic, luminous and jewel are believed to be vulnerable.
CVE-2018-19025 1 Juuko 2 K-808, K-808 Firmware 2024-11-21 9.8 Critical
In JUUKO K-808, an attacker could specially craft a packet that encodes an arbitrary command, which could be executed on the K-808 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.).
CVE-2018-19023 1 Hetronic 10 Bms-hl, Bms-hl Firmware, Dc Mobile and 7 more 2024-11-21 N/A
Hetronic Nova-M prior to verson r161 uses fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state.
CVE-2018-17935 1 Telecrane 22 F25-10d, F25-10d Firmware, F25-10s and 19 more 2024-11-21 8.1 High
All versions of Telecrane F25 Series Radio Controls before 00.0A use fixed codes that are reproducible by sniffing and re-transmission. This can lead to unauthorized replay of a command, spoofing of an arbitrary message, or keeping the controlled load in a permanent "stop" state.
CVE-2018-17932 1 Juuko 2 K-800, K-800 Firmware 2024-11-21 9.8 Critical
JUUKO K-800 (Firmware versions prior to numbers ending ...9A, ...9B, ...9C, etc.) is vulnerable to a replay attack and command forgery, which could allow attackers to replay commands, control the device, view commands, or cause the device to stop running.
CVE-2018-17903 1 Sagaradio 2 Saga1-l8b, Saga1-l8b Firmware 2024-11-21 9.1 Critical
SAGA1-L8B with any firmware versions prior to A0.10 are vulnerable to a replay attack and command forgery.
CVE-2018-17176 1 Neatorobotics 6 Botvac D4 Connected, Botvac D4 Connected Firmware, Botvac D6 Connected and 3 more 2024-11-21 N/A
A replay issue was discovered on Neato Botvac Connected 2.2.0 devices. Manual control mode requires authentication, but once recorded, the authentication (always transmitted in cleartext) can be replayed to /bin/webserver on port 8081. There are no nonces, and timestamps are not checked at all.
CVE-2018-16242 1 O.bike 3 Obike-stationless Bike Sharing, Smart Locker, Smart Locker Firmware 2024-11-21 N/A
oBike relies on Hangzhou Luoping Smart Locker to lock bicycles, which allows attackers to bypass the locking mechanism by using Bluetooth Low Energy (BLE) to replay ciphertext based on a predictable nonce used in the locking protocol.
CVE-2018-15498 1 Ysoft 2 Safeq Server, Safeq Server Client 2024-11-21 N/A
YSoft SafeQ Server 6 allows a replay attack.
CVE-2018-14781 1 Medtronicdiabetes 18 508 Minimed Insulin Pump, 508 Minimed Insulin Pump Firmware, 522 Paradigm Real-time and 15 more 2024-11-21 N/A
Medtronic MMT 508 MiniMed insulin pump, 522 / MMT - 722 Paradigm REAL-TIME, 523 / MMT - 723 Paradigm Revel, 523K / MMT - 723K Paradigm Revel, and 551 / MMT - 751 MiniMed 530G The models identified above, when paired with a remote controller and having the "easy bolus" and "remote bolus" options enabled (non-default), are vulnerable to a capture-replay attack. An attacker can capture the wireless transmissions between the remote controller and the pump and replay them to cause an insulin (bolus) delivery.
CVE-2018-13789 1 Descor 1 Infocad Fm 2024-11-21 N/A
An issue was discovered in Descor Infocad FM before 3.1.0.0. An unauthenticated web service allows the retrieval of files on the web server and on reachable SMB servers.
CVE-2017-5251 1 Insteon 2 Insteon Hub, Insteon Hub Firmware 2024-11-21 N/A
In version 1012 and prior of Insteon's Insteon Hub, the radio transmissions used for communication between the hub and connected devices are not encrypted.
CVE-2013-1351 1 Veraxsystems 1 Network Management System 2024-11-21 5.9 Medium
Verax NMS prior to 2.10 allows authentication via the encrypted password without knowing the cleartext password.