CVE-2025-24423 | 1 Adobe | 1 Commerce B2b | 2025-04-16 | 4.3 Medium |
Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in Privilege escalation. A low-privileged attacker could leverage this vulnerability to modify select data. Exploitation of this issue does not require user interaction. | ||||
CVE-2025-24424 | 1 Adobe | 1 Commerce B2b | 2025-04-16 | 6.5 Medium |
Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized read access. Exploitation of this issue does not require user interaction. | ||||
CVE-2025-24426 | 1 Adobe | 1 Commerce B2b | 2025-04-16 | 6.5 Medium |
Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized read access. Exploitation of this issue does not require user interaction. | ||||
CVE-2021-23173 | 1 Philips | 1 Engage | 2025-04-16 | 2.6 Low |
The affected product is vulnerable to an improper access control, which may allow an authenticated user to gain unauthorized access to sensitive data. | ||||
CVE-2021-23233 | 1 Fresenius-kabi | 8 Agilia Connect, Agilia Connect Firmware, Agilia Partner Maintenance Software and 5 more | 2025-04-16 | 7.3 High |
Sensitive endpoints in Fresenius Kabi Agilia Link+ v3.0 and prior can be accessed without any authentication information such as the session cookie. An attacker can send requests to sensitive endpoints as an unauthenticated user to perform critical actions or modify critical configuration parameters. | ||||
CVE-2020-25160 | 1 Bbraun | 2 Datamodule Compactplus, Spacecom | 2025-04-16 | 6.8 Medium |
Improper access controls in the B. Braun Melsungen AG SpaceCom Version L81/U61 and earlier, and the Data module compactplus Versions A10 and A11 enables attackers to extract and tamper with the devices network configuration. | ||||
CVE-2021-43986 | 1 Fanuc | 1 Roboguide | 2025-04-16 | 6 Medium |
The setup program for the affected product configures its files and folders with full access, which may allow unauthorized users permission to replace original binaries and achieve privilege escalation. | ||||
CVE-2021-33013 | 1 Myscada | 1 Mypro | 2025-04-16 | 8.2 High |
mySCADA myPRO versions prior to 8.20.0 does not restrict unauthorized read access to sensitive system information. | ||||
CVE-2021-27444 | 1 Weintek | 32 Cmt-ctrl01, Cmt-ctrl01 Firmware, Cmt-fhd and 29 more | 2025-04-16 | 9.8 Critical |
The Weintek cMT product line is vulnerable to various improper access controls, which may allow an unauthenticated attacker to remotely access and download sensitive information and perform administrative actions on behalf of a legitimate administrator. | ||||
CVE-2022-1261 | 1 Honeywell | 1 Matrikon Opc Server | 2025-04-16 | 5.8 Medium |
Matrikon, a subsidary of Honeywell Matrikon OPC Server (all versions) is vulnerable to a condition where a low privileged user allowed to connect to the OPC server to use the functions of the IPersisFile to execute operating system processes with system-level privileges. | ||||
CVE-2022-1521 | 1 Illumina | 8 Iseq 100, Local Run Manager, Miniseq and 5 more | 2025-04-16 | 9.1 Critical |
LRM does not implement authentication or authorization by default. A malicious actor can inject, replay, modify, and/or intercept sensitive data. | ||||
CVE-2022-2103 | 1 Secheron | 2 Sepcos Control And Protection Relay, Sepcos Control And Protection Relay Firmware | 2025-04-16 | 9.8 Critical |
An attacker with weak credentials could access the TCP port via an open FTP port, allowing an attacker to read sensitive files and write to remotely executable directories. | ||||
CVE-2022-2088 | 1 Smartics | 1 Smartics | 2025-04-16 | 6.8 Medium |
An authenticated user with admin privileges may be able to terminate any process on the system running Elcomplus SmartICS v2.3.4.0. | ||||
CVE-2022-2792 | 1 Emerson | 1 Electric\'s Proficy | 2025-04-16 | 6.6 Medium |
Emerson Electric's Proficy Machine Edition Version 9.00 and prior is vulenrable to CWE-284 Improper Access Control, and stores project data in a directory with improper access control lists. | ||||
CVE-2022-3027 | 1 Contechealth | 2 Cms8000, Cms8000 Firmware | 2025-04-16 | 5.7 Medium |
The CMS8000 device does not properly control or sanitize the SSID name of a new Wi-Fi access point. A threat actor could create an SSID with a malicious name, including non-standard characters that, when the device attempts connecting to the malicious SSID, the device can be exploited to write arbitrary files or display incorrect information. | ||||
CVE-2022-3382 | 1 Hiwin | 1 Robot System Software | 2025-04-16 | 7.5 High |
HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition. | ||||
CVE-2022-38355 | 1 Daikinlatam | 2 Svmpc1, Svmpc2 | 2025-04-16 | 7.5 High |
Daikin SVMPC1 version 2.1.22 and prior and SVMPC2 version 1.2.3 and prior are vulnerable to attackers with access to the local area network (LAN) to disclose sensitive information stored by the affected product without requiring authentication. | ||||
CVE-2022-38655 | 1 Hcltech | 1 Bigfix Webui | 2025-04-16 | 6.4 Medium |
BigFix WebUI non-master operators are missing controls that prevent them from being able to modify the relevance of fixlets or to deploy fixlets from the BES Support external site. | ||||
CVE-2022-28173 | 1 Hikvision | 4 Ds-3wf01c-2n\/o, Ds-3wf01c-2n\/o Firmware, Ds-3wf0ac-2nt and 1 more | 2025-04-16 | 9.1 Critical |
The web server of some Hikvision wireless bridge products have an access control vulnerability which can be used to obtain the admin permission. The attacker can exploit the vulnerability by sending crafted messages to the affected devices. | ||||
CVE-2025-24429 | 1 Adobe | 3 Commerce, Commerce B2b, Magento | 2025-04-16 | 3.5 Low |
Adobe Commerce versions 2.4.8-beta1, 2.4.7-p3, 2.4.6-p8, 2.4.5-p10, 2.4.4-p11 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass allowing read only access. A low-privileged attacker could leverage this vulnerability to bypass security measures and gain unauthorized access. Exploitation of this issue requires user interaction. |