Filtered by vendor Schneider-electric
Subscriptions
Total
810 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-5296 | 1 Schneider-electric | 1 Software Update Utility | 2026-04-15 | 7.3 High |
| CWE-59: Improper Link Resolution Before File Access ('Link Following') vulnerability exists that could cause arbitrary data to be written to protected locations, potentially leading to escalation of privilege, arbitrary file corruption, exposure of application and system information or persistent denial of service when a low-privileged attacker tampers with the installation folder. | ||||
| CVE-2024-8531 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 7.2 High |
| CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that could compromise the Data Center Expert software when an upgrade bundle is manipulated to include arbitrary bash scripts that are executed as root. | ||||
| CVE-2024-8530 | 1 Schneider-electric | 1 Data Center Expert | 2026-04-15 | 5.9 Medium |
| CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause exposure of private data when an already generated “logcaptures” archive is accessed directly by HTTPS. | ||||
| CVE-2025-8453 | 1 Schneider-electric | 2 Saitel Dp, Saitel Dr | 2026-04-15 | 6.7 Medium |
| CWE-269: Improper Privilege Management vulnerability exists that could cause privilege escalation and arbitrary code execution when a privileged engineer user with console access modifies a configuration file used by a root-level daemon to execute custom scripts. | ||||
| CVE-2025-8448 | 1 Schneider-electric | 2 Ecostruxure Building Operation Enterprise Server, Ecostruxure Workstation | 2026-04-15 | N/A |
| CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause unauthorized access to sensitive credential data when an attacker is able to capture local SMB traffic between a valid user within the BMS network and the vulnerable products. | ||||
| CVE-2024-8936 | 1 Schneider-electric | 1 Modicon M340 | 2026-04-15 | 6.5 Medium |
| CWE-20: Improper Input Validation vulnerability exists that could lead to loss of confidentiality of controller memory after a successful Man-In-The-Middle attack followed by sending a crafted Modbus function call used to tamper with memory. | ||||
| CVE-2025-6625 | 1 Schneider-electric | 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more | 2026-04-15 | 7.5 High |
| CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device. | ||||
| CVE-2025-7746 | 1 Schneider-electric | 1 Altivar | 2026-04-15 | N/A |
| CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause an unvalidated data injected by a malicious user potentially leading to modify or read data in a victim’s browser. | ||||
| CVE-2024-6918 | 1 Schneider-electric | 1 Accutech Manager | 2026-04-15 | 7.5 High |
| CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. | ||||
| CVE-2025-9996 | 1 Schneider-electric | 1 Blmon | 2026-04-15 | N/A |
| CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause the execution of any shell command when executing a netstat command using BLMon Console in an SSH session. | ||||
| CVE-2025-13902 | 1 Schneider-electric | 2 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058 | 2026-03-11 | N/A |
| CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload. | ||||
| CVE-2025-13957 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2026-03-11 | N/A |
| CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default. | ||||
| CVE-2025-13901 | 1 Schneider-electric | 2 Modicon M241/m251, Modicon M262 | 2026-03-11 | N/A |
| CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels. | ||||
| CVE-2025-11739 | 1 Schneider-electric | 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reporting And Dashboards | 2026-03-11 | N/A |
| CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization. | ||||
| CVE-2025-13844 | 1 Schneider-electric | 1 Ecostruxure Power Build - Rapsody | 2026-03-03 | 5.3 Medium |
| CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody. | ||||
| CVE-2023-6407 | 2 Microsoft, Schneider-electric | 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more | 2026-02-25 | 5.3 Medium |
| A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. | ||||
| CVE-2018-1124 | 6 Canonical, Debian, Opensuse and 3 more | 13 Ubuntu Linux, Debian Linux, Leap and 10 more | 2025-12-18 | 7.8 High |
| procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users. | ||||
| CVE-2018-1126 | 5 Canonical, Debian, Procps-ng Project and 2 more | 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more | 2025-12-17 | N/A |
| procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124. | ||||
| CVE-2014-5413 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm. | ||||
| CVE-2014-5412 | 2 Aveva, Schneider-electric | 2 Clearscada, Scada Expert Clearscada | 2025-11-04 | N/A |
| Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account. | ||||