CVE-2023-5909 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more 2024-11-21 7.5 High
KEPServerEX does not properly validate certificates from clients which may allow unauthenticated users to connect.
CVE-2023-5908 4 Ge, Ptc, Rockwellautomation and 1 more 8 Industrial Gateway Server, Keepserverex, Opc-aggregator and 5 more 2024-11-21 9.1 Critical
KEPServerEX is vulnerable to a buffer overflow which may allow an attacker to crash the product being accessed or leak information.
CVE-2023-3463 1 Ge 1 Cimplicity 2024-11-21 6.6 Medium
All versions of GE Digital CIMPLICITY that are not adhering to SDG guidance and accepting documents from untrusted sources are vulnerable to memory corruption issues due to insufficient input validation, including issues such as out-of-bounds reads and writes, use-after-free, stack-based buffer overflows, uninitialized pointers, and a heap-based buffer overflow. Successful exploitation could allow an attacker to execute arbitrary code.
CVE-2022-37953 1 Ge 1 Workstationst 2024-11-21 4.7 Medium
An HTTP response splitting vulnerability exists in the AM Gateway Challenge-Response dialog of WorkstationST (<v07.09.15) and could allow an attacker to compromise a victim's browser/session. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CVE-2022-37952 1 Ge 1 Workstationst 2024-11-21 4.7 Medium
A reflected cross-site scripting (XSS) vulnerability exists in the iHistorian Data Display of WorkstationST (<v07.09.15) could allow an attacker to compromise a victim's browser. WorkstationST is only deployed in specific, controlled environments rendering attack complexity significantly higher than if the attack were conducted on the software in isolation. WorkstationST v07.09.15 can be found in ControlST v07.09.07 SP8 and greater.
CVE-2021-31477 1 Ge 2 Reason Rpv311 Firmware, Rpv311 2024-11-21 7.3 High
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
CVE-2021-27454 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 7.8 High
The software performs an operation at a privilege level higher than the minimum level required, which creates new weaknesses or amplifies the consequences of other weaknesses on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27452 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
The software contains a hard-coded password that could allow an attacker to take control of the merging unit using these hard-coded credentials on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27450 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
SSH server configuration file does not implement some best practices. This could lead to a weakening of the SSH protocol strength, which could lead to additional misconfiguration or be leveraged as part of a larger attack on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27448 1 Ge 2 Mu320e, Mu320e Firmware 2024-11-21 7.8 High
A miscommunication in the file system allows adversaries with access to the MU320E to escalate privileges on the MU320E (all firmware versions prior to v04A00.1).
CVE-2021-27440 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 9.8 Critical
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2021-27438 1 Ge 2 Reason Dr60, Reason Dr60 Firmware 2024-11-21 8.8 High
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1).
CVE-2020-6992 1 Ge 1 Cimplicity 2024-11-21 6.7 Medium
A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.
CVE-2020-6977 1 Ge 32 Invenia Abus Scan Station, Invenia Abus Scan Station Firmware, Logiq E10 and 29 more 2024-11-21 6.8 Medium
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
CVE-2020-27267 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2024-11-21 9.1 Critical
KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
CVE-2020-27265 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2024-11-21 9.8 Critical
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code.
CVE-2020-27263 4 Ge, Ptc, Rockwellautomation and 1 more 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more 2024-11-21 9.1 Critical
KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data.
CVE-2020-16246 1 Ge 4 S2020, S2020 Firmware, S2024 and 1 more 2024-11-21 6.1 Medium
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow attackers to trick users into following a link or navigating to a page that posts a malicious JavaScript statement to the vulnerable site, causing the malicious JavaScript to be rendered by the site and executed by the victim client.
CVE-2020-16244 1 Ge 1 Asset Performance Management Classic 2024-11-21 7.2 High
GE Digital APM Classic, Versions 4.4 and prior. Salt is not used for hash calculation of passwords, making it possible to decrypt passwords. This design flaw, along with the IDOR vulnerability, puts the entire platform at high risk because an authenticated user can retrieve all user account data and then retrieve the actual passwords.
CVE-2020-16242 1 Ge 4 S2020, S2020 Firmware, S2024 and 1 more 2024-11-21 6.1 Medium
The affected Reason S20 Ethernet Switch is vulnerable to cross-site scripting (XSS), which may allow an attacker to trick application users into performing critical application actions that include, but are not limited to, adding and updating accounts.