Filtered by vendor Tenda
Subscriptions
Total
1533 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-9023 | 1 Tenda | 4 Ac18, Ac18 Firmware, Ac7 and 1 more | 2025-10-03 | 8.8 High |
| A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-11091 | 1 Tenda | 2 Ac21, Ac21 Firmware | 2025-10-03 | 8.8 High |
| A security flaw has been discovered in Tenda AC21 up to 16.03.08.16. Affected by this vulnerability is the function sscanf of the file /goform/SetStaticRouteCfg. The manipulation of the argument list results in buffer overflow. The attack can be launched remotely. The exploit has been released to the public and may be exploited. | ||||
| CVE-2025-11123 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 8.8 High |
| A flaw has been found in Tenda AC18 15.03.05.19. This impacts an unknown function of the file /goform/saveAutoQos. This manipulation of the argument enable causes stack-based buffer overflow. The attack may be initiated remotely. The exploit has been published and may be used. | ||||
| CVE-2025-11122 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 8.8 High |
| A vulnerability was detected in Tenda AC18 15.03.05.19. This affects an unknown function of the file /goform/WizardHandle. The manipulation of the argument WANT/mtuvalue results in stack-based buffer overflow. The attack can be launched remotely. The exploit is now public and may be used. | ||||
| CVE-2025-11121 | 1 Tenda | 2 Ac18, Ac18 Firmware | 2025-10-03 | 6.3 Medium |
| A security vulnerability has been detected in Tenda AC18 15.03.05.19. The impacted element is an unknown function of the file /goform/AdvSetLanip. The manipulation of the argument lanIp leads to command injection. The attack can be initiated remotely. The exploit has been disclosed publicly and may be used. | ||||
| CVE-2025-11120 | 1 Tenda | 3 Ac18, Ac18 Firmware, Ac8 | 2025-10-03 | 8.8 High |
| A weakness has been identified in Tenda AC8 16.03.34.06. The affected element is the function formSetServerConfig of the file /goform/SetServerConfig. Executing manipulation can lead to buffer overflow. It is possible to launch the attack remotely. The exploit has been made available to the public and could be exploited. | ||||
| CVE-2025-11117 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-10-03 | 8.8 High |
| A vulnerability was determined in Tenda CH22 1.0.0.1. This vulnerability affects the function formWrlExtraGet of the file /goform/GstDhcpSetSer. This manipulation of the argument dips causes buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. | ||||
| CVE-2025-55606 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2025-09-26 | 9.8 Critical |
| Tenda AX3 V16.03.12.10_CN is vulnerable to Buffer Overflow in the fromAdvSetMacMtuWan function via the serverName parameter. | ||||
| CVE-2025-55605 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2025-09-26 | 9.8 Critical |
| Tenda AX3 V16.03.12.10_CN is vulnerable to Buffer Overflow in the saveParentControlInfo function via the deviceName parameter. | ||||
| CVE-2025-55603 | 1 Tenda | 2 Ax3, Ax3 Firmware | 2025-09-26 | 9.8 Critical |
| Tenda AX3 V16.03.12.10_CN is vulnerable to Buffer Overflow in the fromSetSysTime function via the ntpServer parameter. | ||||
| CVE-2025-9007 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-09-26 | 8.8 High |
| A vulnerability has been found in Tenda CH22 1.0.0.1. Affected by this issue is the function formeditFileName of the file /goform/editFileName. The manipulation leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-9006 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-09-26 | 8.8 High |
| A vulnerability was identified in Tenda CH22 1.0.0.1. Affected by this vulnerability is the function formdelFileName of the file /goform/delFileName. The manipulation leads to buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-57296 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-09-25 | 6.5 Medium |
| Tenda AC6 router firmware 15.03.05.19 contains a command injection vulnerability in the formSetIptv function, which processes requests to the /goform/SetIPTVCfg web interface. When handling the list and vlanId parameters, the sub_ADBC0 helper function concatenates these user-supplied values into nvram set system commands using doSystemCmd, without validating or sanitizing special characters (e.g., ;, ", #). An unauthenticated or authenticated attacker can exploit this by submitting a crafted POST request, leading to arbitrary system command execution on the affected device. | ||||
| CVE-2025-10815 | 1 Tenda | 2 Ac20, Ac20 Firmware | 2025-09-25 | 8.8 High |
| A vulnerability was identified in Tenda AC20 up to 16.03.08.12. Affected by this issue is the function strcpy of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. The attack can be launched remotely. The exploit is publicly available and might be used. | ||||
| CVE-2025-57639 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2025-09-25 | 6.5 Medium |
| OS Command injection vulnerability in Tenda AC9 1.0 was discovered to contain a command injection vulnerability via the usb.samba.guest.user parameter in the formSetSambaConf function of the httpd file. | ||||
| CVE-2025-57638 | 1 Tenda | 2 Ac9, Ac9 Firmware | 2025-09-25 | 7.5 High |
| Buffer overflow vulnerability in Tenda AC9 1.0 via the user supplied sys.vendor configuration value. | ||||
| CVE-2025-10803 | 1 Tenda | 2 Ac23, Ac23 Firmware | 2025-09-24 | 8.8 High |
| A vulnerability has been found in Tenda AC23 up to 16.03.07.52. Affected by this vulnerability is the function sscanf of the file /goform/SetPptpServerCfg of the component HTTP POST Request Handler. Such manipulation of the argument startIp leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2025-9523 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2025-09-20 | 9.8 Critical |
| A vulnerability was detected in Tenda AC1206 15.03.06.23. Affected is the function GetParentControlInfo of the file /goform/GetParentControlInfo. The manipulation of the argument mac results in stack-based buffer overflow. It is possible to launch the attack remotely. The exploit is now public and may be used. | ||||
| CVE-2025-10432 | 1 Tenda | 2 Ac1206, Ac1206 Firmware | 2025-09-20 | 9.8 Critical |
| A vulnerability was found in Tenda AC1206 15.03.06.23. This vulnerability affects the function check_param_changed of the file /goform/AdvSetMacMtuWa of the component HTTP Request Handler. Performing manipulation of the argument wanMTU results in stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit has been made public and could be used. | ||||
| CVE-2025-10442 | 1 Tenda | 4 Ac15, Ac15 Firmware, Ac9 and 1 more | 2025-09-19 | 6.3 Medium |
| A vulnerability was determined in Tenda AC9 and AC15 15.03.05.14. This affects the function formexeCommand of the file /goform/exeCommand. This manipulation of the argument cmdinput causes os command injection. Remote exploitation of the attack is possible. The exploit has been publicly disclosed and may be utilized. | ||||