Filtered by CWE-284
Total 3733 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-24042 1 Microsoft 1 Visual Studio Code 2025-07-02 7.3 High
Visual Studio Code JS Debug Extension Elevation of Privilege Vulnerability
CVE-2025-4433 1 Devolutions 1 Devolutions Server 2025-07-02 8.8 High
Improper access control in user group management in Devolutions Server 2025.1.7.0 and earlier allows a non-administrative user with both "User Management" and "User Group Management" permissions to perform privilege escalation by adding users to groups with administrative privileges.
CVE-2025-5382 1 Devolutions 1 Devolutions Server 2025-07-02 6.8 Medium
Improper access control in users MFA feature in Devolutions Server 2025.1.7.0 and earlier allows a user with user management permission to remove or change administrators MFA.
CVE-2025-0691 1 Devolutions 1 Devolutions Server 2025-07-02 5 Medium
Improper access control in permissions component in Devolutions Server 2025.1.10.0 and earlier allows an authenticated user to bypass the "Edit permission" permission by bypassing the client side validation.
CVE-2025-3768 1 Devolutions 1 Devolutions Server 2025-07-02 5 Medium
Improper access control in Tor network blocking feature in Devolutions Server 2025.1.10.0 and earlier allows an authenticated user to bypass the tor blocking feature when the Devolutions hosted endpoint is not reachable.
CVE-2025-5108 1 Shopxo 1 Shopxo 2025-07-02 6.3 Medium
A vulnerability was found in zongzhige ShopXO 6.5.0. It has been rated as critical. This issue affects the function Upload of the file app/admin/controller/Payment.php of the component ZIP File Handler. The manipulation of the argument params leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-30138 1 Gnetsystem 2 G-onx, G-onx Firmware 2025-07-01 4.6 Medium
An issue was discovered on G-Net Dashcam BB GONX devices. Managing Settings and Obtaining Sensitive Data and Sabotaging Car Battery can be performed by unauthorized persons. It allows unauthorized users to modify critical system settings once connected to its network. Attackers can extract sensitive car and driver information, mute dashcam alerts to prevent detection, disable recording functionality, or even factory reset the device. Additionally, they can disable battery protection, causing the dashcam to drain the car battery when left on overnight. These actions not only compromise privacy but also pose potential physical harm by rendering the dashcam non-functional or causing vehicle battery failure.
CVE-2025-30141 1 Gnetsystem 2 G-onx, G-onx Firmware 2025-07-01 7.5 High
An issue was discovered on G-Net Dashcam BB GONX devices. One can Remotely Dump Video Footage and the Live Video Stream. It exposes API endpoints on ports 9091 and 9092 that allow remote access to recorded and live video feeds. An attacker who connects to the dashcam's network can retrieve all stored recordings and convert them from JDR format to MP4. Additionally, port 9092's RTSP stream can be accessed remotely, allowing real-time video feeds to be extracted without the owner's knowledge.
CVE-2025-30140 1 Gnetsystem 2 G-onx, G-onx Firmware 2025-07-01 7.5 High
An issue was discovered on G-Net Dashcam BB GONX devices. A Public Domain name is Used for the Internal Domain Name. It uses an unregistered public domain name as an internal domain, creating a security risk. This domain was not owned by GNET originally, allowing an attacker to register it and potentially intercept sensitive device traffic (it has since been registered by the vulnerability discoverer). If the dashcam or related services attempt to resolve this domain over the public Internet instead of locally, it could lead to data exfiltration or man-in-the-middle attacks.
CVE-2025-31698 1 Apache 1 Traffic Server 2025-07-01 7.5 High
ACL configured in ip_allow.config or remap.config does not use IP addresses that are provided by PROXY protocol. Users can use a new setting (proxy.config.acl.subjects) to choose which IP addresses to use for the ACL if Apache Traffic Server is configured to accept PROXY protocol.  This issue affects undefined: from 10.0.0 through 10.0.6, from 9.0.0 through 9.2.10. Users are recommended to upgrade to version 9.2.11 or 10.0.6, which fixes the issue.
CVE-2025-6873 1 Oretnom23 1 Simple Company Website 2025-07-01 4.7 Medium
A vulnerability, which was classified as critical, has been found in SourceCodester Simple Company Website 1.0. This issue affects some unknown processing of the file /classes/Users.php?f=save. The manipulation of the argument img leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-6872 1 Oretnom23 1 Simple Company Website 2025-07-01 4.7 Medium
A vulnerability classified as critical was found in SourceCodester Simple Company Website 1.0. This vulnerability affects unknown code of the file /classes/SystemSettings.php?f=update_settings. The manipulation of the argument img leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-6870 1 Oretnom23 1 Simple Company Website 2025-07-01 4.7 Medium
A vulnerability was found in SourceCodester Simple Company Website 1.0. It has been rated as critical. Affected by this issue is some unknown functionality of the file /classes/Content.php?f=service. The manipulation of the argument img leads to unrestricted upload. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-45729 1 Dlink 2 Dir-823 Pro, Dir-823 Pro Firmware 2025-07-01 6.3 Medium
D-Link DIR-823-Pro 1.02 has improper permission control, allowing unauthorized users to turn on and access Telnet services.
CVE-2025-6837 1 Code-projects 1 Library System 2025-07-01 6.3 Medium
A vulnerability classified as critical was found in code-projects Library System 1.0. Affected by this vulnerability is an unknown functionality of the file /profile.php. The manipulation of the argument image leads to unrestricted upload. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.
CVE-2025-6900 1 Code-projects 1 Library System 2025-07-01 6.3 Medium
A vulnerability has been found in code-projects Library System 1.0 and classified as critical. This vulnerability affects unknown code of the file /add-book.php. The manipulation of the argument image leads to unrestricted upload. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2024-23920 1 Chargepoint 6 Home Flex Hardwired, Home Flex Hardwired Firmware, Home Flex Nema 14-50 Plug and 3 more 2025-07-01 8.8 High
This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of ChargePoint Home Flex charging stations. Authentication is not required to exploit this vulnerability. The specific flaw exists within the onboardee module. The issue results from improper access control. An attacker can leverage this vulnerability to execute code in the context of root.
CVE-2025-6848 1 Fabianros 1 Simple Forum 2025-07-01 6.3 Medium
A vulnerability, which was classified as critical, has been found in code-projects Simple Forum 1.0. This issue affects some unknown processing of the file /forum1.php. The manipulation of the argument File leads to unrestricted upload. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.
CVE-2012-6442 1 Rockwellautomation 22 1100, 1400, 1756-enbt and 19 more 2025-06-30 N/A
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that instructs the product to reset, a DoS can occur. This situation could cause loss of availability and a disruption of communication with other connected devices. Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400
CVE-2012-6439 1 Rockwellautomation 17 1756-enbt, 1756-eweb, 1768-enbt and 14 more 2025-06-30 N/A
When an affected product receives a valid CIP message from an unauthorized or unintended source to Port 2222/TCP, Port 2222/UDP, Port 44818/TCP, or Port 44818/UDP that changes the product’s configuration and network parameters, a DoS condition can occur. This situation could cause loss of availability and a disruption of communication with other connected devices.  Rockwell Automation EtherNet/IP products; 1756-ENBT, 1756-EWEB, 1768-ENBT, and 1768-EWEB communication modules; CompactLogix L32E and L35E controllers; 1788-ENBT FLEXLogix adapter; 1794-AENTR FLEX I/O EtherNet/IP adapter; ControlLogix 18 and earlier; CompactLogix 18 and earlier; GuardLogix 18 and earlier; SoftLogix 18 and earlier; CompactLogix controllers 19 and earlier; SoftLogix controllers 19 and earlier; ControlLogix controllers 20 and earlier; GuardLogix controllers 20 and earlier; and MicroLogix 1100 and 1400