Filtered by vendor Moxa Subscriptions
Total 311 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2025-1679 1 Moxa 4 Tn-4500a, Tn-5500a, Tn-g4500 and 1 more 2026-04-15 N/A
Cross-site Scripting has been identified in Moxa’s Ethernet switches, which allows an authenticated administrative attacker to inject malicious scripts to an affected device’s web service that could impact authenticated users interacting with the device’s web interface. This vulnerability is classified as stored cross-site scripting (XSS); attackers inject malicious scripts into the system, and the scripts persist across sessions. There is no impact to the confidentiality, integrity, and availability of the affected device; no loss of availability within any subsequent systems but has some loss of confidentiality and integrity within the subsequent system.
CVE-2025-1680 1 Moxa 4 Tn-4500a, Tn-5500a, Tn-g4500 and 1 more 2026-04-15 N/A
An acceptance of extraneous untrusted data with trusted data vulnerability has been identified in Moxa’s Ethernet switches, which allows attackers with administrative privileges to manipulate HTTP Host headers by injecting a specially crafted Host header into HTTP requests sent to an affected device’s web service. This vulnerability is classified as Host Header Injection, where invalid Host headers can manipulate to redirect users, forge links, or phishing attacks. There is no impact to the confidentiality, integrity, and availability of the affected device; no loss of confidentiality, integrity, and availability within any subsequent systems.
CVE-2025-1977 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by an execution with unnecessary privileges vulnerability (CVE-2025-1977) that allows an authenticated user with read-only access to perform unauthorized configuration changes through the MCC (Moxa CLI Configuration) tool. The issue can be exploited remotely over the network with low-attack complexity and no user interaction but requires specific system conditions or configurations to be present. Successful exploitation may result in changes to device settings that were not intended to be permitted for the affected user role, potentially leading to a high impact on the confidentiality, integrity, and availability of the device. No impact on other systems has been identified.
CVE-2025-6892 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Incorrect Authorization vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in the API authentication mechanism allows unauthorized access to protected API endpoints, including those intended for administrative functions. This vulnerability can be exploited after a legitimate user has logged in, as the system fails to properly validate session context or privilege boundaries. An attacker may leverage this flaw to perform unauthorized privileged operations. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-6950 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Use of Hard-coded Credentials vulnerability has been identified in Moxa’s network security appliances and routers. The system employs a hard-coded secret key to sign JSON Web Tokens (JWT) used for authentication. This insecure implementation allows an unauthenticated attacker to forge valid tokens, thereby bypassing authentication controls and impersonating any user. Exploitation of this vulnerability can result in complete system compromise, enabling unauthorized access, data theft, and full administrative control over the affected device. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2024-9139 1 Moxa 8 Edf-g1002-bp Firmware, Edr-8010 Firmware, Edr-810 Firmware and 5 more 2026-04-15 7.2 High
The affected product permits OS command injection through improperly restricted commands, potentially allowing attackers to execute arbitrary code.
CVE-2025-6893 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A flaw in broken access control has been identified in the /api/v1/setting/data endpoint of the affected device. This flaw allows a low-privileged authenticated user to call the API without the required permissions, thereby gaining the ability to access or modify system configuration data. Successful exploitation may lead to privilege escalation, allowing the attacker to access or modify sensitive system settings. While the overall impact is high, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-6949 1 Moxa 7 Edf-g1002-bp, Edr-8010, Edr-g9010 and 4 more 2026-04-15 N/A
An Execution with Unnecessary Privileges vulnerability has been identified in Moxa’s network security appliances and routers. A critical authorization flaw in the API allows an authenticated, low-privileged user to create a new administrator account, including accounts with usernames identical to existing users. In certain scenarios, this vulnerability could allow an attacker to gain full administrative control over the affected device, leading to potential account impersonation. While successful exploitation can severely impact the confidentiality, integrity, and availability of the affected device itself, there is no loss of confidentiality or integrity within any subsequent systems.
CVE-2025-2026 1 Moxa 2 Nport 6100-g2 Series, Nport 6200-g2 Series 2026-04-15 N/A
The NPort 6100-G2/6200-G2 Series is affected by a high-severity vulnerability (CVE-2025-2026) that allows remote attackers to execute a null byte injection through the device’s web API. This may lead to an unexpected device reboot and result in a denial-of-service (DoS) condition. An authenticated remote attacker with web read-only privileges can exploit the vulnerable API to inject malicious input. Successful exploitation may cause the device to reboot, disrupting normal operations and causing a temporary denial of service.
CVE-2025-15017 1 Moxa 11 Nport 5000ai-m12 Series, Nport 5100 Series, Nport 5100a Series and 8 more 2026-04-15 N/A
A vulnerability exists in serial device servers where active debug code remains enabled in the UART interface. An attacker with physical access to the device can directly connect to the UART interface and, without authentication, user interaction, or execution conditions, gain unauthorized access to internal debug functionality. Exploitation is low complexity and allows an attacker to execute privileged operations and access sensitive system resources, resulting in a high impact to the confidentiality, integrity, and availability of the affected device. No security impact to external or dependent systems has been identified.
CVE-2026-4483 1 Moxa 1 Mxgeneralio 2026-04-08 N/A
An exposed IOCTL with an  insufficient access control vulnerability has been identified in the utility, MxGeneralIo, for Moxa’s industrial x86 computers. The affected utility, MxGeneralIo, exposes IOCTL methods that permit direct read and write access to MSR and system memory. A local attacker with high privileges could abuse these interfaces to perform unauthorized operations. Successful exploitation may result in privilege escalation on Windows 7 systems or cause a system crash (BSoD) on Windows 10 and 11 systems, leading to a denial-of-service condition. The vulnerability could slightly affect the confidentiality and integrity of the device, but availability might be heavily impacted. No impact to the subsequent system has been identified.
CVE-2022-41313 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="switch_contact"
CVE-2022-41312 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="Switch Description", name "switch_description"
CVE-2022-41311 1 Moxa 4 Sds-3008, Sds-3008-t, Sds-3008-t Firmware and 1 more 2025-11-04 5.4 Medium
A stored cross-site scripting vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to arbitrary Javascript execution. An attacker can send an HTTP request to trigger this vulnerability.Form field id="webLocationMessage_text" name="webLocationMessage_text"
CVE-2016-9346 1 Moxa 6 Miineport E1, Miineport E1 Firmware, Miineport E2 and 3 more 2025-04-20 N/A
An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. Configuration data are stored in a file that is not encrypted.
CVE-2016-9332 1 Moxa 1 Softcms 2025-04-20 N/A
An issue was discovered in Moxa SoftCMS versions prior to Version 1.6. Moxa SoftCMS Webserver does not properly validate input. An attacker could provide unexpected values and cause the program to crash or excessive consumption of resources could result in a denial-of-service condition.
CVE-2017-14028 1 Moxa 6 Nport 5110, Nport 5110 Firmware, Nport 5130 and 3 more 2025-04-20 N/A
A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets.
CVE-2017-13703 1 Moxa 2 Eds-g512e, Eds-g512e Firmware 2025-04-20 N/A
An issue was discovered on MOXA EDS-G512E 5.1 build 16072215 devices. A denial of service may occur.
CVE-2016-8719 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 6.1 Medium
An exploitable reflected Cross-Site Scripting vulnerability exists in the Web Application functionality of Moxa AWK-3131A Wireless Access Point running firmware 1.1. Specially crafted input, in multiple parameters, can cause a malicious scripts to be executed by a victim.
CVE-2016-8722 1 Moxa 2 Awk-3131a, Awk-3131a Firmware 2025-04-20 5.3 Medium
An exploitable Information Disclosure vulnerability exists in the Web Application functionality of Moxa AWK-3131A Series Industrial IEEE 802.11a/b/g/n wireless AP/bridge/client. Retrieving a specific URL without authentication can reveal sensitive information to an attacker.