Filtered by vendor Tenda
Subscriptions
Filtered by product Ac10
Subscriptions
Total
74 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-27021 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the formSetFirewallCfg function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27020 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the saveParentControlInfo function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2023-27018 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-02-12 | 9.8 Critical |
Tenda AC10 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the sub_45EC1C function. This vulnerability allows attackers to cause a Denial of Service (DoS) or execute arbitrary code via a crafted payload. | ||||
CVE-2024-2581 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-22 | 8.8 High |
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability. | ||||
CVE-2023-34568 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/PowerSaveSet. | ||||
CVE-2023-34566 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 9.8 Critical |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter time at /goform/saveParentControlInfo. | ||||
CVE-2023-34571 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter shareSpeed at /goform/WifiGuestSet. | ||||
CVE-2023-34570 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter devName at /goform/SetOnlineDevName. | ||||
CVE-2023-34569 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetNetControlList. | ||||
CVE-2023-34567 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2025-01-06 | 6.7 Medium |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter list at /goform/SetVirtualServerCfg. | ||||
CVE-2024-2856 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2023-45484 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic. | ||||
CVE-2023-45483 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time. | ||||
CVE-2023-45482 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info. | ||||
CVE-2023-45481 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the firewallEn parameter in the function SetFirewallCfg. | ||||
CVE-2023-45480 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the src parameter in the function sub_47D878. | ||||
CVE-2023-45479 | 1 Tenda | 2 Ac10, Ac10 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the list parameter in the function sub_49E098. | ||||
CVE-2023-42320 | 1 Tenda | 3 Ac10, Ac10 Firmware, Ac10v4 | 2024-11-21 | 9.8 Critical |
Buffer Overflow vulnerability in Tenda AC10V4 v.US_AC10V4.0si_V16.03.10.13_cn_TDC01 allows a remote attacker to cause a denial of service via the mac parameter in the GetParentControlInfo function. | ||||
CVE-2023-40901 | 1 Tenda | 3 Ac10, Ac10v4, Ac10v4 Firmware | 2024-11-21 | 9.8 Critical |
Tenda AC10 v4 US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via parameter macFilterType and parameter deviceList at url /goform/setMacFilterCfg. | ||||
CVE-2023-38937 | 1 Tenda | 14 Ac10, Ac10 Firmware, Ac1206 and 11 more | 2024-11-21 | 9.8 Critical |
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. |