Total
12746 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-5853 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-06-09 | 8.8 High |
A vulnerability classified as critical was found in Tenda AC6 15.03.05.16. Affected by this vulnerability is the function formSetSafeWanWebMan of the file /goform/SetRemoteWebCfg. The manipulation of the argument remoteIp leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-5855 | 1 Tenda | 2 Ac6, Ac6 Firmware | 2025-06-09 | 8.8 High |
A vulnerability, which was classified as critical, was found in Tenda AC6 15.03.05.16. This affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2024-49350 | 1 Ibm | 1 Db2 | 2025-06-09 | 6.5 Medium |
IBM Db2 for Linux, UNIX and Windows (includes DB2 Connect Server) 11.1.0 through 11.1.4.7, 11.5.0 through 11.5.9 and 12.1.0 through 12.1.1 is vulnerable to a denial of service as the server may crash under certain conditions with a specially crafted query. | ||||
CVE-2024-21175 | 2 Bea, Oracle | 2 Weblogic Server, Weblogic Server | 2025-06-09 | 7.5 High |
Vulnerability in the Oracle WebLogic Server product of Oracle Fusion Middleware (component: Core). Supported versions that are affected are 12.2.1.4.0 and 14.1.1.0.0. Easily exploitable vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle WebLogic Server. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle WebLogic Server accessible data. CVSS 3.1 Base Score 7.5 (Integrity impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N). | ||||
CVE-2024-53901 | 1 Tonycoz | 1 Imager | 2025-06-09 | 5.5 Medium |
The Imager package before 1.025 for Perl has a heap-based buffer overflow leading to denial of service, or possibly unspecified other impact, when the trim() method is called on a crafted input image. | ||||
CVE-2024-0542 | 1 Tenda | 2 W9, W9 Firmware | 2025-06-09 | 8.8 High |
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. Affected by this issue is the function formWifiMacFilterGet of the component httpd. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-250712. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2024-24188 | 1 Jsish | 1 Jsish | 2025-06-09 | 9.8 Critical |
Jsish v3.5.0 was discovered to contain a heap-buffer-overflow in ./src/jsiUtils.c. | ||||
CVE-2025-5481 | 2025-06-09 | N/A | ||
Sante DICOM Viewer Pro DCM File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Sante DICOM Viewer Pro. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of DCM files. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated object. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-26168. | ||||
CVE-2019-12900 | 7 Bzip, Canonical, Debian and 4 more | 9 Bzip2, Ubuntu Linux, Debian Linux and 6 more | 2025-06-09 | 9.8 Critical |
BZ2_decompress in decompress.c in bzip2 through 1.0.6 has an out-of-bounds write when there are many selectors. | ||||
CVE-2022-29072 | 2 7-zip, Microsoft | 2 7-zip, Windows | 2025-06-09 | 7.8 High |
7-Zip through 21.07 on Windows allows privilege escalation and command execution when a file with the .7z extension is dragged to the Help>Contents area. This is caused by misconfiguration of 7z.dll and a heap overflow. The command runs in a child process under the 7zFM.exe process. NOTE: multiple third parties have reported that no privilege escalation can occur | ||||
CVE-2021-38185 | 2 Gnu, Redhat | 2 Cpio, Enterprise Linux | 2025-06-09 | 7.8 High |
GNU cpio through 2.13 allows attackers to execute arbitrary code via a crafted pattern file, because of a dstring.c ds_fgetstr integer overflow that triggers an out-of-bounds heap write. NOTE: it is unclear whether there are common cases where the pattern file, associated with the -E option, is untrusted data. | ||||
CVE-2025-5527 | 1 Tenda | 2 Rx3, Rx3 Firmware | 2025-06-09 | 8.8 High |
A vulnerability was found in Tenda RX3 16.03.13.11_multi_TDE01. It has been rated as critical. This issue affects the function save_staticroute_data of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-5619 | 1 Tenda | 2 Ch22, Ch22 Firmware | 2025-06-06 | 8.8 High |
A vulnerability, which was classified as critical, has been found in Tenda CH22 1.0.0.1. This issue affects the function formaddUserName of the file /goform/addUserName. The manipulation of the argument Password leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. | ||||
CVE-2025-23103 | 1 Samsung | 4 Exynos 1480, Exynos 1480 Firmware, Exynos 2400 and 1 more | 2025-06-06 | 8.6 High |
An issue was discovered in Samsung Mobile Processor Exynos 1480 and 2400. The lack of a length check leads to out-of-bounds writes. | ||||
CVE-2025-23107 | 1 Samsung | 4 Exynos 1480, Exynos 1480 Firmware, Exynos 2400 and 1 more | 2025-06-06 | 8.6 High |
An issue was discovered in Samsung Mobile Processor Exynos 1480 and 2400. The lack of a length check leads to out-of-bounds writes. | ||||
CVE-2025-5572 | 1 Dlink | 2 Dcs-932l, Dcs-932l Firmware | 2025-06-06 | 8.8 High |
A vulnerability was found in D-Link DCS-932L 2.18.01. It has been declared as critical. Affected by this vulnerability is the function setSystemEmail of the file /setSystemEmail. The manipulation of the argument EmailSMTPPortNumber leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. | ||||
CVE-2025-23097 | 1 Samsung | 2 Exynos 1380, Exynos 1380 Firmware | 2025-06-06 | 9.1 Critical |
An issue was discovered in Samsung Mobile Processor Exynos 1380. The lack of a length check leads to out-of-bounds writes. | ||||
CVE-2023-51955 | 1 Tenda | 2 Ax1803, Ax1803 Firmware | 2025-06-06 | 6.5 Medium |
Tenda AX1803 v1.0.0.1 contains a stack overflow via the adv.iptv.stballvlans parameter in the function formSetIptv. | ||||
CVE-2025-5502 | 1 Totolink | 2 X15, X15 Firmware | 2025-06-06 | 6.3 Medium |
A vulnerability, which was classified as critical, has been found in TOTOLINK X15 1.0.0-B20230714.1105. Affected by this issue is the function formMapReboot of the file /boafrm/formMapReboot. The manipulation of the argument deviceMacAddr leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. | ||||
CVE-2025-5624 | 1 Dlink | 2 Dir-816, Dir-816 Firmware | 2025-06-06 | 9.8 Critical |
A vulnerability was found in D-Link DIR-816 1.10CNB05. It has been declared as critical. This vulnerability affects the function QoSPortSetup of the file /goform/QoSPortSetup. The manipulation of the argument port0_group/port0_remarker/ssid0_group/ssid0_remarker leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. This vulnerability only affects products that are no longer supported by the maintainer. |