CVE-2023-37198 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | 6.8 Medium |
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause remote code execution when an admin user on DCE uploads or tampers with install packages. | ||||
CVE-2023-37197 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | 8.8 High |
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the mass configuration settings of endpoints on DCE. | ||||
CVE-2023-37196 | 1 Schneider-electric | 1 Struxureware Data Center Expert | 2024-11-21 | 8.8 High |
A CWE-89: Improper Neutralization of Special Elements vulnerability used in an SQL Command ('SQL Injection') vulnerability exists that could allow a user already authenticated on DCE to access unauthorized content, change, or delete content, or perform unauthorized actions when tampering with the alert settings of endpoints on DCE. | ||||
CVE-2023-2570 | 1 Schneider-electric | 1 Ecostruxure Foxboro Dcs Control Core Services | 2024-11-21 | 7 High |
A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious actor with local user access crafts a script/program using an unpredictable index to an IOCTL call in the Foxboro.sys driver. | ||||
CVE-2023-29414 | 1 Schneider-electric | 1 Accutech Manager | 2024-11-21 | 7.8 High |
A CWE-120: Buffer Copy without Checking Size of Input (Classic Buffer Overflow) vulnerability exists that could cause user privilege escalation if a local user sends specific string input to a local function call. | ||||
CVE-2023-28004 | 1 Schneider-electric | 2 Powerlogic Hdpm6000, Powerlogic Hdpm6000 Firmware | 2024-11-21 | 9.8 Critical |
A CWE-129: Improper validation of an array index vulnerability exists where a specially crafted Ethernet request could result in denial of service or remote code execution. | ||||
CVE-2022-37302 | 1 Schneider-electric | 1 Ecostruxure Control Expert | 2024-11-21 | 5.5 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior). | ||||
CVE-2022-37300 | 1 Schneider-electric | 70 Ecostruxure Control Expert, Ecostruxure Process Expert, Modicon M340 Bmxp341000 and 67 more | 2024-11-21 | 9.8 Critical |
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340 CPU (part numbers BMXP34*) (V3.40 and prior), Modicon M580 CPU (part numbers BMEP* and BMEH*) (V3.20 and prior). | ||||
CVE-2022-34765 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.5 Medium |
A CWE-73: External Control of File Name or Path vulnerability exists that could cause loading of unauthorized firmware images when user-controlled data is written to the file path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34764 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service when parsing the URL. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34763 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists that could cause loading of unauthorized firmware images due to improper verification of the firmware signature. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34762 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 5.9 Medium |
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized firmware image loading when unsigned images are added to the firmware image path. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34761 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 7.5 High |
A CWE-476: NULL Pointer Dereference vulnerability exists that could cause a denial of service of the webserver when parsing JSON content type. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V2.01 and later), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34760 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 7.5 High |
A CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') vulnerability exists that could cause a denial of service of the webserver due to improper handling of the cookies. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34759 | 1 Schneider-electric | 4 Opc Ua Module For M580, Opc Ua Module For M580 Firmware, X80 Advanced Rtu Module and 1 more | 2024-11-21 | 7.5 High |
A CWE-787: Out-of-bounds Write vulnerability exists that could cause a denial of service of the webserver due to improper parsing of the HTTP Headers. Affected Products: X80 advanced RTU Communication Module (BMENOR2200H) (V1.0), OPC UA Modicon Communication Module (BMENUA0100) (V1.10 and prior) | ||||
CVE-2022-34758 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | 5.1 Medium |
A CWE-20: Improper Input Validation vulnerability exists that could cause the device watchdog function to be disabled if the attacker had access to privileged user credentials. Affected Products: Easergy P5 (V01.401.102 and prior) | ||||
CVE-2022-34757 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | 6.7 Medium |
A CWE-327: Use of a Broken or Risky Cryptographic Algorithm vulnerability exists where weak cipher suites can be used for the SSH connection between Easergy Pro software and the device, which may allow an attacker to observe protected communication details. Affected Products: Easergy P5 (V01.401.102 and prior) | ||||
CVE-2022-34756 | 1 Schneider-electric | 2 Easergy P5, Easergy P5 Firmware | 2024-11-21 | 8.8 High |
A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution or the crash of HTTPs stack which is used for the device Web HMI. Affected Products: Easergy P5 (V01.401.102 and prior) | ||||
CVE-2022-34754 | 1 Schneider-electric | 4 Acti9 Powertag Link C \(a9xelc10-a\), Acti9 Powertag Link C \(a9xelc10-a\) Firmware, Acti9 Powertag Link C \(a9xelc10-b\) and 1 more | 2024-11-21 | 6.8 Medium |
A CWE-269: Improper Privilege Management vulnerability exists that could allow elevated functionality when guessing credentials. Affected Products: Acti9 PowerTag Link C (A9XELC10-A) (V1.7.5 and prior), Acti9 PowerTag Link C (A9XELC10-B) (V2.12.0 and prior) | ||||
CVE-2022-34753 | 1 Schneider-electric | 2 Spacelogic C-bus Home Controller, Spacelogic C-bus Home Controller Firmware | 2024-11-21 | 8.8 High |
A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause remote root exploit when the command is compromised. Affected Products: SpaceLogic C-Bus Home Controller (5200WHC2), formerly known as C-Bus Wiser Homer Controller MK2 (V1.31.460 and prior) |