799 CVE
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2017-2341 | 1 Juniper | 13 Acx5000, Ex4600, Junos and 10 more | 2025-04-20 | N/A |
| An insufficient authentication vulnerability on platforms where Junos OS instances are run in a virtualized environment, may allow unprivileged users on the Junos OS instance to gain access to the host operating environment, and thus escalate privileges. Affected releases are Juniper Networks Junos OS 14.1X53 prior to 14.1X53-D40 on QFX5110, QFX5200, QFX10002, QFX10008, QFX10016, EX4600 and NFX250; 15.1 prior to 15.1R5 on EX4600; 15.1X49 prior to 15.1X49-D70 on vSRX, SRX1500, SRX4100, SRX4200; 16.1 prior to 16.1R2 on EX4600, ACX5000 series. This issue does not affect vMX. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10604 | 1 Juniper | 2 Junos, Srx | 2025-04-20 | N/A |
| When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series. | ||||
| CVE-2016-4924 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8 | ||||
| CVE-2017-10618 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| When the 'bgp-error-tolerance' feature â€" designed to help mitigate remote session resets from malformed path attributes â€" is enabled, a BGP UPDATE containing a specifically crafted set of transitive attributes can cause the RPD routing process to crash and restart. Devices with BGP enabled that do not have 'bgp-error-tolerance' configured are not vulnerable to this issue. Affected releases are Juniper Networks Junos OS 13.3 prior to 13.3R10-S2; 14.1 prior to 14.1R8-S4, 14.1R9; 14.1X50 prior to 14.1X50-D185; 14.1X53 prior to 14.1X53-D45, 14.1X53-D50; 14.2 prior to 14.2R7-S7, 14.2R8; 15.1 prior to 15.1F5-S8, 15.1F6-S7, 15.1R5-S6, 15.1R6-S2, 15.1R7; 15.1X49 prior to 15.1X49-D100; 15.1X53 prior to 15.1X53-D64, 15.1X53-D70; 16.1 prior to 16.1R3-S4, 16.1R4-S3, 16.1R5; 16.2 prior to 16.2R1-S5, 16.2R2; 17.1 prior to 17.1R1-S3, 17.1R2; 17.2 prior to 17.2R1-S2, 17.2R2; 17.2X75 prior to 17.2X75-D50. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2016-7103 | 7 Debian, Fedoraproject, Jqueryui and 4 more | 13 Debian Linux, Fedora, Jquery Ui and 10 more | 2025-04-20 | 6.1 Medium |
| Cross-site scripting (XSS) vulnerability in jQuery UI before 1.12.0 might allow remote attackers to inject arbitrary web script or HTML via the closeText parameter of the dialog function. | ||||
| CVE-2016-1261 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| J-Web does not validate certain input that may lead to cross-site request forgery (CSRF) issues or cause a denial of J-Web service (DoS). | ||||
| CVE-2017-10610 | 1 Juniper | 2 Junos, Srx Series | 2025-04-20 | N/A |
| On SRX Series devices, a crafted ICMP packet embedded within a NAT64 IPv6 to IPv4 tunnel may cause the flowd process to crash. Repeated crashes of the flowd process constitutes an extended denial of service condition for the SRX Series device. This issue only occurs if NAT64 is configured. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D71, 12.3X48 prior to 12.3X48-D55, 15.1X49 prior to 15.1X49-D100 on SRX Series. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-2342 | 1 Juniper | 2 Junos, Srx300 | 2025-04-20 | N/A |
| MACsec feature on Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series does not report errors when a secure link can not be established. It falls back to an unencrypted link. This can happen when MACsec is configured on ports that are not capable of MACsec or when a secure link can not be established. This can mislead customers into believing that a link is secure. On SRX 300 series devices, prior to 15.1X49-D100, MACsec was only supported on control and fabric ports of SRX340 and SRX345 devices. SRX300 and and SRX320 did not have any MACsec capable ports. Configuring MACsec on ports that were not MACsec capable would have resulted in this issue. Affected releases are Juniper Networks Junos OS 15.1X49 prior to 15.1X49-D100 on SRX300 series. | ||||
| CVE-2017-2302 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks products or platforms running Junos OS 12.1X46 prior to 12.1X46-D55, 12.1X47 prior to 12.1X47-D45, 12.3R13 prior to 12.3R13, 12.3X48 prior to 12.3X48-D35, 13.3 prior to 13.3R10, 14.1 prior to 14.1R8, 14.1X53 prior to 14.1X53-D40, 14.1X55 prior to 14.1X55-D35, 14.2 prior to 14.2R6, 15.1 prior to 15.1F2 or 15.1R1, 15.1X49 prior to 15.1X49-D20 where the BGP add-path feature is enabled with 'send' option or with both 'send' and 'receive' options, a network based attacker can cause the Junos OS rpd daemon to crash and restart. Repeated crashes of the rpd daemon can result in an extended denial of service condition. | ||||
| CVE-2017-2349 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A command injection vulnerability in the IDP feature of Juniper Networks Junos OS on SRX series devices potentially allows a user with login access to the device to execute shell commands and elevate privileges. Affected releases are Juniper Networks Junos OS 12.1X44 prior to 12.1X44-D60; 12.1X46 prior to 12.1X46-D50; 12.1X47 prior to 12.1X47-D30, 12.1X47-D35; 12.3X48 prior to 12.3X48-D20, 12.3X48-D30; 15.1X49 prior to 15.1X49-D20, 15.1X49-D30. | ||||
| CVE-2017-10614 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A vulnerability in telnetd service on Junos OS allows a remote attacker to cause a limited memory and/or CPU consumption denial of service attack. This issue was found during internal product security testing. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D45; 12.3X48 prior to 12.3X48-D30; 14.1 prior to 14.1R4-S9, 14.1R8; 14.2 prior to 14.2R6; 15.1 prior to 15.1F5, 15.1R3; 15.1X49 prior to 15.1X49-D40; 15.1X53 prior to 15.1X53-D232, 15.1X53-D47. | ||||
| CVE-2017-10611 | 1 Juniper | 15 Ex2200, Ex3300, Junos and 12 more | 2025-04-20 | N/A |
| If extended statistics are enabled via 'set chassis extended-statistics', when executing any operation that fetches interface statistics, including but not limited to SNMP GET requests, the pfem process or the FPC may crash and restart. Repeated crashes of PFE processing can result in an extended denial of service condition. This issue only affects the following platforms: (1) EX2200, EX3300, XRE200 (2) MX Series routers with MPC7E/8E/9E PFEs installed, and only if 'extended-statistics' are enabled under the [edit chassis] configuration. Affected releases are Juniper Networks Junos OS 14.1 prior to 14.1R8-S5, 14.1R9 on MX Series; 14.1X53 prior to 14.1X53-D46, 14.1X53-D50 on EX2200, EX3300, XRE200; 14.2 prior to 14.2R7-S9, 14.2R8 on MX Series; 15.1 prior to 15.1F5-S8, 15.1F6-S8, 15.1R5-S3, 15.1R6 on MX Series; 16.1 prior to 16.1R4-S5, 16.1R5, 16.1R6 on MX Series; 16.1X65 prior to 16.1X65-D45 on EX2200, EX3300, XRE200; 16.2 prior to 16.2R2-S1, 16.2R3 on MX Series; 17.1 prior to 17.1R2-S2, 17.1R3 on MX Series; 17.2 prior to 17.2R1-S3, 17.2R2 on MX Series; 17.2X75 prior to 17.2X75-D50 on MX Series; 17.3 prior to 17.3R1-S1, 17.3R2 on MX Series. No other Juniper Networks products or platforms are affected by this issue. | ||||
| CVE-2017-10619 | 1 Juniper | 7 Junos, Srx1400, Srx3400 and 4 more | 2025-04-20 | N/A |
| When Express Path (formerly known as service offloading) is configured on Juniper Networks SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800 in high availability cluster configuration mode, certain multicast packets might cause the flowd process to crash, halting or interrupting traffic from flowing through the device and triggering RG1+ (data-plane) fail-over to the secondary node. Repeated crashes of the flowd process may constitute an extended denial of service condition. This service is not enabled by default and is only supported in high-end SRX platforms. Affected releases are Juniper Networks Junos OS 12.3X48 prior to 12.3X48-D45, 15.1X49 prior to 15.1X49-D80 on SRX1400, SRX3400, SRX3600, SRX5400, SRX5600, SRX5800. | ||||
| CVE-2017-10607 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| Juniper Networks Junos OS 16.1R1, and services releases based off of 16.1R1, are vulnerable to the receipt of a crafted BGP Protocol Data Unit (PDU) sent directly to the router, which can cause the RPD routing process to crash and restart. Unlike BGP UPDATEs, which are transitive in nature, this issue can only be triggered by a packet sent directly to the IP address of the router. Repeated crashes of the rpd daemon can result in an extended denial of service condition. This issue only affects devices running Junos OS 16.1R1 and services releases based off of 16.1R1 (e.g. 16.1R1-S1, 16.1R1-S2, 16.1R1-S3). No prior versions of Junos OS are affected by this vulnerability, and this issue was resolved in Junos OS 16.2 prior to 16.2R1. No other Juniper Networks products or platforms are affected by this issue. This issue was found during internal product security testing. | ||||
| CVE-2017-10605 | 1 Juniper | 14 Junos, Srx100, Srx110 and 11 more | 2025-04-20 | N/A |
| On all vSRX and SRX Series devices, when the DHCP or DHCP relay is configured, specially crafted packet might cause the flowd process to crash, halting or interrupting traffic from flowing through the device(s). Repeated crashes of the flowd process may constitute an extended denial of service condition for the device(s). If the device is configured in high-availability, the RG1+ (data-plane) will fail-over to the secondary node. If the device is configured in stand-alone, there will be temporary traffic interruption until the flowd process is restored automatically. Sustained crafted packets may cause the secondary failover node to fail back, or fail completely, potentially halting flowd on both nodes of the cluster or causing flip-flop failovers to occur. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D67 on vSRX or SRX Series; 12.3X48 prior to 12.3X48-D50 on vSRX or SRX Series; 15.1X49 prior to 15.1X49-D91, 15.1X49-D100 on vSRX or SRX Series. | ||||
| CVE-2017-10602 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A buffer overflow vulnerability in Junos OS CLI may allow a local authenticated user with read only privileges and access to Junos CLI, to execute code with root privileges. Affected releases are Juniper Networks Junos OS: 14.1X53 versions prior to 14.1X53-D46 on EX2200/VC, EX3200, EX3300/VC, EX4200, EX4300, EX4550/VC, EX4600, EX6200, EX8200/VC (XRE), QFX3500, QFX3600, QFX5100; 14.1X53 versions prior to 14.1X53-D130 on QFabric System; 14.2 versions prior to 14.2R4-S9, 14.2R6; 15.1 versions prior to 15.1F5, 15.1R3; 15.1X49 versions prior to 15.1X49-D40 on SRX Series; 15.1X53 versions prior to 15.1X53-D47 on NFX150, NFX250; 15.1X53 versions prior to 15.1X53-D65 on QFX10000 Series; 15.1X53 versions prior to 15.1X53-D233 on QFX5110, QFX5200. | ||||
| CVE-2017-2300 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks SRX Series Services Gateways chassis clusters running Junos OS 12.1X46 prior to 12.1X46-D65, 12.3X48 prior to 12.3X48-D40, 12.3X48 prior to 12.3X48-D60, flowd daemon on the primary node of an SRX Series chassis cluster may crash and restart when attempting to synchronize a multicast session created via crafted multicast packets. | ||||
| CVE-2017-10601 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A specific device configuration can result in a commit failure condition. When this occurs, a user is logged in without being prompted for a password while trying to login through console, ssh, ftp, telnet or su, etc., This issue relies upon a device configuration precondition to occur. Typically, device configurations are the result of a trusted administrative change to the system's running configuration. The following error messages may be seen when this failure occurs: mgd: error: commit failed: (statements constraint check failed) Warning: Commit failed, activating partial configuration. Warning: Edit the router configuration to fix these errors. If the administrative changes are not made that result in such a failure, then this issue is not seen. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 12.3 prior to 12.3R10, 12.3R11; 12.3X48 prior to 12.3X48-D20; 13.2 prior to 13.2R8; 13.3 prior to 13.3R7; 14.1 prior to 14.1R4-S12, 14.1R5, 14.1R6; 14.1X53 prior to 14.1X53-D30; 14.2 prior to 14.2R4; 15.1 prior to 15.1F2, 15.1F3, 15.1R2. | ||||
| CVE-2017-2312 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| On Juniper Networks devices running Junos OS affected versions and with LDP enabled, a specific LDP packet destined to the RE (Routing Engine) will consume a small amount of the memory allocated for the rpd (routing protocol daemon) process. Over time, repeatedly receiving this type of LDP packet(s) will cause the memory to exhaust and the rpd process to crash and restart. It is not possible to free up the memory that has been consumed without restarting the rpd process. This issue affects Junos OS based devices with either IPv4 or IPv6 LDP enabled via the [protocols ldp] configuration (the native IPv6 support for LDP is available in Junos OS 16.1 and higher). The interface on which the packet arrives needs to have LDP enabled. The affected Junos versions are: 13.3 prior to 13.3R10; 14.1 prior to 14.1R8; 14.2 prior to 14.2R7-S6 or 14.2R8; 15.1 prior to 15.1F2-S14, 15.1F6-S4, 15.1F7, 15.1R4-S7, 15.1R5; 15.1X49 before 15.1X49-D70; 15.1X53 before 15.1X53-D230, 15.1X53-D63, 15.1X53-D70; 16.1 before 16.1R2. 16.2R1 and all subsequent releases have a resolution for this vulnerability. | ||||
| CVE-2017-10621 | 1 Juniper | 1 Junos | 2025-04-20 | N/A |
| A denial of service vulnerability in telnetd service on Juniper Networks Junos OS allows remote unauthenticated attackers to cause a denial of service. Affected Junos OS releases are: 12.1X46 prior to 12.1X46-D71; 12.3X48 prior to 12.3X48-D50; 14.1 prior to 14.1R8-S5, 14.1R9; 14.1X53 prior to 14.1X53-D50; 14.2 prior to 14.2R7-S9, 14.2R8; 15.1 prior to 15.1F2-S16, 15.1F5-S7, 15.1F6-S6, 15.1R5-S2, 15.1R6; 15.1X49 prior to 15.1X49-D90; 15.1X53 prior to 15.1X53-D47; 16.1 prior to 16.1R4-S1, 16.1R5; 16.2 prior to 16.2R1-S3, 16.2R2; | ||||